A global outbreak of invasive Mycobacterium chimaera infections after cardiac surgery has recently been linked to bioaerosols from contaminated heater-cooler units. The majority of cases have occurred after valvular surgery or aortic graft surgery and nearly half have resulted in death. To date, infections in patients with left ventricular assist devices (LVADs) have not been characterized in the literature. We report two cases of device-associated M. chimaera infection in patients with continuous-flow LVADs and describe challenges related to diagnosis and management in this population.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/jocs.13150 | DOI Listing |
Sci Rep
December 2024
Microbiology Unit, IRCCS Azienda Ospedaliero-Universitaria of Bologna, Bologna, Italy.
Mycobacterium chimaera, belonging to the Mycobacterium avium complex, is an opportunistic environmental mycobacterium which has been isolated from medical device water samples such as Heater Cooler Units (HCU). Laboratories currently use culture-based diagnostic methods to detect M. chimaera, but these take a long time to obtain results.
View Article and Find Full Text PDFJ Clin Microbiol
December 2024
Laboratoire de Bactériologie, CHU Bordeaux, Bordeaux, France.
Accurate identification of non-tuberculous mycobacterial (NTM) species is crucial for the diagnosis and appropriate management of NTM infections. This study aimed to evaluate the performance of two assays, FluoroType Mycobacteria VER 1.0 and Maldi BioTyper (MBT) Mycobacteria.
View Article and Find Full Text PDFJ Hosp Infect
January 2025
Department of Public Health and Pediatrics, University of Turin, Turin, Italy.
Front Public Health
October 2024
Department of Biomedical Sciences Laboratory, Affiliated Dongyang Hospital of Wenzhou Medical University, Dongyang, Zhejiang, China.
Pathogens
September 2024
Department of Health Sciences, University of Genova, Via Pastore 1, 16132 Genova, Italy.
(MC), a member of the complex, can cause infections in patients after open-heart surgery due to contaminated heater-cooler units (HCUs). The transmission route of HCU-related MC infection is non-inhalational, and infection can occur in patients without previously known immune deficiency. Patients may develop endocarditis of the prosthetic valve, infection of the vascular graft, and/or manifestations of disseminated mycobacterial infection (splenomegaly, arthritis, hepatitis, nephritis, myocarditis, etc.