Background: Specific treatment of the volar marginal rim fragment of distal radius fractures avoids occurance of volar radiocarpal dislocation. Although several fixation systems are available to capture this fragment, adequately maintaining internal fixation is difficult. We present our experience of the first 10 cases using the 2.4 mm variable angle LCP volar rim distal radius plate (Depuy Synthes®, West Chester, US), a low-profile volar rim-contouring plate designed for distal plate positioning and stable buttressing of the volar marginal fragment.
Methods: Follow-up patient satisfaction, range of motion, grips strength, functional scoring with the QuickDASH and residual pain with a numeric rating scale were assessed. Radiological evaluation consisted in evaluating fracture consolidation, ulnar variance, volar angulation and maintenance of the volar rim fixation.
Results: The female to male ratio was 5:5 and the mean age was 52.2 (range, 17-80) years. The mean follow-up period was 11 (range, 5-19) months postoperatively. Patient satisfaction was high. The mean total flexion/extension range was 144° (range, 100-180°) compared to the contralateral uninjured side 160° (range, 95-180°). The mean total pronation/supination range was 153° (range, 140-180°) compared to the contralateral uninjured side 170° (range, 155-180°). Mean grip strength was 14 kg (range, 9-22), compared to the contralateral uninjured side 20 kg (range, 12-25 kg). Mean pre-injury level activity QuickDASH was 23 (range, 0-34.1), while post-recovery QuickDASH was 25 (range 0-43.2). Residual pain was 1.5 on the visual numerical pain rating scale. Radiological evaluation revealed in all cases fracture consolidation, satisfactory reconstruction of ulnar variance, volar angulation and volar rim. We encountered no flexor tendon complications, although plate removal was systematically performed after fracture consolidation.
Conclusions: The 2.4 mm variable angle LCP volar rim distal radius plates is a valid treatment option for treating the volar marginal fragment in distal radius fractures.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1142/S0218810417500228 | DOI Listing |
J Hand Surg Eur Vol
January 2025
Department of Orthopedics, E-Da Hospital, I-Shou University/School of Medicine, College of Medicine, I-Shou University, Kaohsiung, Taiwan.
Treatment of distal radial fractures that include small anterior rim fragments can be difficult. We retrospectively reviewed 19 patients in whom an anterior rim plate with locking screws was used. After a median follow-up of 18 months (range 6-32; interquartile range (IQR) 14, 26), the median wrist flexion and extension arc was 70° (range 50-80; IQR 60, 70), the median grip strength was 80% of the contralateral side (range 52-104; IQR 77, 88), the median visual analogue scale score for pain was 0 (range 0-5; IQR 0, 1), the median disabilities of the arm, shoulder and hand score was 2 (range 0-59; IQR 0, 11) and the median modified Mayo wrist score was 80 (range 35-100; IQR 75, 85).
View Article and Find Full Text PDFRev Bras Ortop (Sao Paulo)
December 2024
Departamento de Ortopedia, Traumatologia e Cirurgia da Mão, Faculdade de Medicina, Ankara University, Altındağ, Ankara, Turquia.
To assess the efficacy of distal radius volar plates in cases involving dorsal fragments at the Ulnar Corner (UC) and Lister Tubercle (LT). A retrospective study that included patients with distal radius fractures (DRFs) featuring UC and LT dorsal fragments treated with volar plates. The exclusion criteria comprised lunate facet fractures, UC fragment ratio below 25%, and patients treated with dorsal plates.
View Article and Find Full Text PDFCureus
October 2024
Trauma and Orthopaedic Surgery, Alexandria Faculty of Medicine, Alexandria, EGY.
Introduction Volar rim fragment fixation is difficult to manage, as it is distal to the watershed line, rendering normal volar plates unable to securely capture it. This fragment must be precisely addressed as volar carpal subluxation is unavoidable when fixation is not efficient. The spring-wire technique maintains a stable fixation of this key fragment, which has been previously described in a small series.
View Article and Find Full Text PDFJ Hand Surg Glob Online
March 2024
Harvard Medical School, Boston, MA.
Purpose: The objective of this study was to determine the risk factors and the rate of reoperation after closed reduction percutaneous pinning (CRPP) of isolated closed single-digit proximal phalanx fractures.
Methods: A retrospective cohort study was conducted for patients who underwent CRPP of non-thumb closed proximal phalanx fractures between 2010 and 2020 at two level-I trauma centers and two community teaching hospitals. Demographics, fracture, and treatment characteristics were collected.