A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Quantitative Online Liquid Chromatography-Surface-Enhanced Raman Scattering (LC-SERS) of Methotrexate and its Major Metabolites. | LitMetric

The application of Raman spectroscopy as a detection method coupled with liquid chromatography (LC) has recently attracted considerable interest, although this has currently been limited to isocratic elution. The combination of LC with rapidly advancing Raman techniques, such as surface-enhanced Raman scattering (SERS), allows for rapid separation, identification and quantification, leading to quantitative discrimination of closely eluting analytes. This study has demonstrated the utility of SERS in conjunction with reversed-phase liquid chromatography (RP-LC), for the detection and quantification of the therapeutically relevant drug molecule methotrexate (MTX) and its metabolites 7-hydroxy methotrexate (7-OH MTX) and 2,4-diamino-N(10)-methylpteroic acid (DAMPA) in pure solutions and mixtures, including spikes into human urine from a healthy individual and patients under medication. While the RP-LC analysis developed employed gradient elution, where the chemical constituents of the mobile phase were modified stepwise during analysis, this did not overtly interfere with the SERS signals. In addition, the practicability and clinical utility of this approach has also been demonstrated using authentic patients' urine samples. Here, the identification of MTX, 7-OH MTX and DAMPA are based on their unique SERS spectra, providing limits of detection of 2.36, 1.84, and 3.26 μM respectively. Although these analytes are amenable to LC and LC-MS detection an additional major benefit of the SERS approach is its applicability toward the detection of analytes that do not show UV absorption or are not ionised for mass spectrometry (MS)-based detection. The results of this study clearly demonstrate the potential application of online LC-SERS analysis for real-time high-throughput detection of drugs and their related metabolites in human biofluids.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.analchem.7b00916DOI Listing

Publication Analysis

Top Keywords

raman scattering
8
liquid chromatography
8
7-oh mtx
8
detection
7
sers
5
quantitative online
4
online liquid
4
liquid chromatography-surface-enhanced
4
raman
4
chromatography-surface-enhanced raman
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!