Objective: The main purpose of the present systematic review was to evaluate the quantitative effects of the pendulum appliance and modified pendulum appliances for maxillary molar distalization in Class II malocclusion.
Materials And Methods: Our systematic search included MEDLINE, EMBASE, CINAHL, PsychINFO, Scopus and key journals and review articles; the date of the last search was 30 January 2017. We graded the methodological quality of the studies by means of the Quality Assessment Tool for Quantitative Studies, developed for the Effective Public Health Practice Project (EPHPP).
Results: In total, 203 studies were identified for screening, and 25 studies were eligible. The quality assessment rated four (16%) of the study as being of strong quality and 21 (84%) of these studies as being of moderate quality. The pendulum appliances showed mean molar distalization of 2-6.4 mm, distal tipping of molars from 6.67° to 14.50° and anchorage loss with mean premolar and incisor mesial movement of 1.63-3.6 mm and 0.9-6.5 mm, respectively. The bone anchored pendulum appliances (BAPAs) showed mean molar distalization of 4.8-6.4 mm, distal tipping of molars from 9° to 11.3° and mean premolar distalization of 2.7-5.4 mm.
Conclusions: Pendulum and modified pendulum appliances are effective in molar distalization. Pendulum appliance with K-loop modification, implant supported pendulum appliance and BAPA significantly reduced anchorage loss of the anterior teeth and distal tipping of the molar teeth.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1080/00016357.2017.1324636 | DOI Listing |
Am J Orthod Dentofacial Orthop
January 2025
Department of Orthodontics, Bauru Dental School, University of São Paulo, Bauru, Brazil.
Introduction: The objective of this study was to compare the dental and skeletal changes promoted by the miniscrew-anchored cantilever and pendulum appliance for Class II correction.
Methods: This retrospective study involved 52 patients with Class II malocclusion divided into 2 groups according to the treatment received: the miniscrew group (MG) with 23 patients (14 females and 9 males; mean initial age of 12.42 years) treated using the miniscrew-anchored cantilever, and the pendulum group (PG) with 29 patients (21 females and 8 males; mean initial age of 13.
Gait Posture
October 2024
Institute of Rehabilitation, Jamk University of Applied Sciences, Jyväskylä, Finland; Gerontology Research Center (GEREC), Faculty of Sport and Health Sciences, University of Jyväskylä, Jyväskylä, Finland; The Wellbeing servicescounty of Central Finland, Jyväskylä, Finland. Electronic address:
Introduction: IMU sensors (three-dimensional accelerometer, gyroscope and magnetometer) enable assessment of walking in older adults outside the laboratory. We studied whether IMUs are valid for detecting walking parameters (step events, time, length, and cadence) in a laboratory and outdoors on a level surface in older adults.
Methods: This validation study is part of a larger cross-sectional study.
Head Face Med
October 2024
Department of Biomedical, Surgical and Dental Sciences, University of Milan, Milan, Italy.
Objectives: The purpose of this multicenter retrospective study was to perform a two-dimensional analysis of upper airway changes in adolescent patients following molar distalization with the Pendulum appliance.
Materials And Methods: The study involved the cephalometric analysis of 88 patients, retrospectively categorized into two groups: skeletal Class II with a dental Class II molar relationship (36 patients, mean age 12.6 ± 1.
ACS Appl Mater Interfaces
October 2024
School of Automation, Chongqing University of Posts and Telecommunications, Chongqing 400065, China.
Human biomechanical energy, with features of fluctuating amplitudes and low frequency, has been considered as a potential sustainable power source for wearable healthcare monitoring devices. Developing an effective energy harvester to ensure robust energy harvesting efficiency remains highly desired. Herein, we propose a wearable pendulum-rotor-separated triboelectric-electromagnetic hybrid generator (PTEHG).
View Article and Find Full Text PDFA 20-year-old female patient with severe maxillary crowding and skeletal Class III malocclusion was successfully treated using an enhanced pendulum appliance. Camouflage treatment was chosen because the patient refused surgical intervention. Detailed examination and analysis revealed that labial inclination of the maxillary anterior teeth could provide the alignment space necessary after tooth extraction in the maxillary arch but it would not be beneficial esthetically and would increase the moment perpendicular to the tooth long axis as well as increase the risk of bone dehiscence.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!