A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Calibration transfer between different analytical methods. | LitMetric

Calibration transfer between different analytical methods.

Talanta

Institute of Chemistry, St. Petersburg State University, St. Petersburg, Russia; Laboratory of artificial sensory systems, ITMO University, St. Petersburg, Russia.

Published: August 2017

The procedure for transfer of calibration models between different analytical methods is suggested. It is based on the direct standardization (DS) algorithm earlier suggested for data conversion between physically different instruments of the same type. As a result, multivariate regression models obtained e.g. for NIR spectroscopic measurements in one wavelength range can be successfully applied for predictions from the data obtained with another NIR spectrometer in another wavelength range. The performance of the suggested method was tested with two simulated and two real datasets. In the latter case calibration models constructed for energy-dispersive X-ray fluorescence, UV-Vis spectrometry and NIR spectrometry were addressed. The observed performance of the method implies that it can have a broad range of possible applications in analytical chemistry; some of them are suggested in the paper.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2017.04.039DOI Listing

Publication Analysis

Top Keywords

analytical methods
8
calibration models
8
wavelength range
8
calibration transfer
4
transfer analytical
4
methods procedure
4
procedure transfer
4
transfer calibration
4
models analytical
4
suggested
4