BACKGROUND We used indocyanine green (ICG) fluorescence imaging to completely resect lymphatic malformations (LMs). This is the first report of navigation surgery utilizing ICG fluorescence imaging for resection of LMs. CASE REPORT A 15-year-old boy was diagnosed with LMs in the abdominal wall. The extent of the tumor was determined by an ultrasound, and ICG (Diagnogreen®, Daiichi-Sankyo Pharma, Tokyo, Japan) was injected subcutaneously and intradermally into the core and 2 marginal regions of the tumor (3 injections in total), respectively. During surgery, the extent of the tumor was confirmed with a photodynamic eye, and the tumor was completely resected. A fluorescent portion macroscopically estimated as normal was additionally resected and no residual fluorescence or tumor were confirmed in the remaining tissue. Abnormal lymphatic vessels were histopathologically observed in the additionally resected tissue, indicating the invasion of LMs. The surgery had a good outcome with no evidence of recurrence. CONCLUSIONS We performed near-infrared fluorescence-guided imaging surgery for the resection of LMs in the abdominal wall. This is a single case study; therefore, assessment of more cases is warranted for further validation. This procedure could provide significant benefit to patients requiring resection of LMs.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5439529PMC
http://dx.doi.org/10.12659/ajcr.903465DOI Listing

Publication Analysis

Top Keywords

fluorescence imaging
12
resection lms
12
navigation surgery
8
surgery resection
8
lymphatic malformations
8
indocyanine green
8
icg fluorescence
8
lms abdominal
8
abdominal wall
8
extent tumor
8

Similar Publications

Super-resolution methods provide far better spatial resolution than the optical diffraction limit of about half the wavelength of light (∼200-300 nm). Nevertheless, they have yet to attain widespread use in plants, largely due to plants' challenging optical properties. Expansion microscopy improves effective resolution by isotropically increasing the physical distances between sample structures while preserving relative spatial arrangements and clearing the sample.

View Article and Find Full Text PDF

Purpose: A relative afferent pupillary defect (RAPD) is a characteristic clinical sign of optic neuritis (ON). Here, we systematically evaluated ultrasound pupillometry (UP) for the detection of an RAPD in patients with ON, including a comparison with infrared video pupillometry (IVP), the gold standard for objective pupillometry.

Materials And Methods: We enrolled 40 patients with acute (n = 9) or past (n = 31) ON (ON+), 31 patients with multiple sclerosis (MS) without prior ON, and 50 healthy controls (HC) in a cross-sectional observational study.

View Article and Find Full Text PDF

Antimicrobial peptides (AMPs) are promising agents for treating antibiotic-resistant bacterial infections. Although discovering novel AMPs is crucial for combating multidrug-resistant bacteria and biofilm-related infections, their clinical potential relies on precise, real-time evaluation of efficacy, toxicity, and mechanisms. Optical diffraction tomography (ODT), a label-free imaging technology, enables real-time visualization of bacterial morphological changes, membrane damage, and biofilm formation over time.

View Article and Find Full Text PDF

Importance: Determining spectacle-corrected visual acuity (VA) is essential when managing many ophthalmic diseases. If artificial intelligence (AI) evaluations of macular images estimated this VA from a fundus image, AI might provide spectacle-corrected VA without technician costs, reduce visit time, or facilitate home monitoring of VA from fundus images obtained outside of the clinic.

Objective: To estimate spectacle-corrected VA measured on a standard eye chart among patients with diabetic macular edema (DME) in clinical practice settings using previously validated AI algorithms evaluating best-corrected VA from fundus photographs in eyes with DME.

View Article and Find Full Text PDF

This study addresses the critical issue of irreversible oxidation in hypochlorite (ClO⁻) sensing by a phenothiazine-based compound, which typically leads to the probe's degradation and loss of functionality. We introduce a novel fluorescence probe, (2-(5-(10 H-phenothiazin-10-yl)thiophen-2-yl)-1 H-benzo[d]imidazol-6-yl)(phenyl)methanone (PTH-BP), specifically designed to enhance ClO⁻ detection efficiency. PTH-BP exhibits strong aggregation-induced emission (AIE), emitting deep orange fluorescence at 620 nm with a large Stokes shift of 195 nm, and achieves an impressive detection limit of 1 nM in ACN/PBS buffer solutions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!