Change in over-refraction after scleral lens settling on average corneas.

Ophthalmic Physiol Opt

School of Optometry and Vision Science, University of Waterloo, Waterloo, Canada.

Published: July 2017

Purpose: The purpose of this study was to determine the change in over-refraction, if any, after a scleral lens settled on the eye for 6-8 h.

Methods: Sixteen patients of varying refractive errors and normal corneal curvatures (measured with Pentacam Oculus) were fitted with trial Mini-Scleral Design (MSD) scleral lenses (15.8 mm diameter) in one eye. The sagittal depths of the scleral lenses were selected by adding 350 μm to the corneal sagittal heights measured at a chord length of 15 mm with the Visante optical coherence tomographer (OCT) anterior segment scans and picking the closest available trial lens in the set. Initial measurements were taken 30 min after lens insertion and included an auto-refraction, subjective refraction, and best sphere refraction over the contact lens. Visual acuities and Visante OCT anterior segment scans were also taken. These measurements were repeated after 6-8 h of lens wear.

Results: Over the trial wearing period, the average change in the spherical component of the over-refraction was +0.06 D (S.D. 0.17) (p = 0.16). The average change in cylinder was +0.04 D (S.D. 0.19) (p = 0.33). The average absolute change in axis was 1.06° (S.D. 12.11) (p = 0.74). The average change in best sphere was +0.13 ± 0.30 D (p = 0.12). There was no significant change in visual acuity with the best sphere over-refraction over the 6-8 h wearing period. There was a significant change in central corneal clearance over the wearing period of 83 μm (S.D. 22) (p < 0.0001).

Conclusion: Despite a significant change in the central corneal clearance due to thinning of the fluid reservoir as the scleral lens settled (an average decrease of 83 μm after wearing the lenses for 6-8 h), there was not a statistically significant change in the subjective over-refraction (sphere, cylinder, and axis) or best sphere or visual acuity. This study has confirmed that there is no link between reduction in central corneal clearance and change in over-refraction for average corneas.

Download full-text PDF

Source
http://dx.doi.org/10.1111/opo.12380DOI Listing

Publication Analysis

Top Keywords

best sphere
12
wearing period
12
average change
12
change
8
change over-refraction
8
over-refraction scleral
8
scleral lens
8
scleral lenses
8
oct anterior
8
anterior segment
8

Similar Publications

Background: Substandard and falsified medicines in Africa are a major public health concern. Access to quality medical products in African countries is governed in large part by two major entities at the national level: the regulatory authority and the procurement agency. The importance of national regulators in ensuring quality medical products is well known.

View Article and Find Full Text PDF

Background And Objective: Migrant and refugee women, families, and their children can experience significant language, cultural, and psychosocial barriers to engage with child and family services. Integrated child and family health Hubs are increasingly promoted as a potential solution to address access barriers; however, there is scant literature on how to best implement them with migrant and refugee populations. Our aim was to explore with service providers and consumers the barriers, enablers, and experiences with Hubs and the resulting building blocks required for acceptable Hub implementation for migrant and refugee families.

View Article and Find Full Text PDF

Unveiling the rural dichotomy: the dual impact of rurality on youth mental health.

Rural Remote Health

January 2025

Rural Clinical School Western Australia, University of Western Australia, UWA Science Building, Albany, WA 6330, Australia.

Introduction: The geographic, cultural, social and economic milieu that impacts mental health in rural communities globally has been well documented. However, few studies have addressed how rural ecosystems impact specifically upon the mental health and wellbeing of young people. Furthermore, the limited explorations of factors contributing to poorer mental health outcomes in rural youth have primarily included adult voices.

View Article and Find Full Text PDF

Soil is regarded as a natural repository for strongly adsorbed pollutants since glyphosate (GLY) is preferentially adsorbed by the inorganic fraction of the soil, which may greatly limits its leaching. In this way, understanding how clay mineralogy influences the sorption and transport processes of glyphosate in soils with different mineralogical characteristics is highly relevant. In this work, two clay mineralogy contrasting soils were used to evaluate GLY retention: a Oxisol (OX) with high levels of iron oxides (amorphous and crystalline) and a Inceptisol (IN) with a predominance of kaolinite.

View Article and Find Full Text PDF

Fabrication of 3D printed hollow spheres for quality control and feasibility for use with xSPECT bone.

Phys Eng Sci Med

December 2024

Department of Medical Imaging and Nuclear Medicine, Gosford Hospital, Building K3, Gosford, NSW, Australia.

Quantitative accuracy and constancy of Siemens xSPECT Bone quantitative reconstruction algorithm (xBone) can be monitored using activity-filled hollow spheres, which could be 3D printed (3DP) to increase accessibility to phantoms. One concern is that 3D prints can have air gaps in the walls which may pose issues for attenuation correction and xBone tissue zone mapping. This study assessed the feasibility of using 3DP spheres (3DP-S) with materials PLA, PETG and Resin as substitutes for commercial hollow spheres (C-S).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!