Background: Most of the experience on fenestrated endovascular aneurysm repair involves the custom-made Zenith endograft (Cook). The fenestrated Anaconda endograft (Vascutek) was introduced with the potential advantages of complete repositioning and lack of stent material on the main aortic body for more versatility. However, few data are available. Our objective was to assess its mid-term results in the treatment of complex aortic aneurysms.
Methods: Consecutive patients treated with the custom-made fenestrated Anaconda endograft in France and the Principality of Monaco, from December 2010 to October 2015, were included.
Results: Eighty-six patients were included over 16 centers (82 men, mean age 73.4 ± 8.1 years, 16 (18.6%) symptomatic aneurysms). The repositioning system was used in 68 cases (79.1%). Two hundred ninety-two visceral/renal vessels were targeted, with a mean number of 3.4 ± 0.6 target vessels/patient and a successful reconstruction in 99.3% of the cases (290/292 vessels). Perioperative technical success was achieved in 86.0% (74/86 patients). In-hospital and 30-day mortality rates were 3.5% (3 patients) and 7.0% (6 patients), respectively. At 12 and 24 months, estimated overall survival rate was 88.3% and 85.2%, target vessel's patency rate was 97.2% and 96.3%, and freedom from aneurysm-related reintervention rate was 96.3% and 88.0%, respectively. At 24 months, there were 7 type II endoleaks (12.7%) and a significant reduction in aneurysm maximum transverse diameter in 70.4%. Five limb occlusions occurred at 1-year and 1 at 2-year follow-up (7.0%).
Conclusions: The fenestrated Anaconda stent-graft system offers acceptable technical success rates, mid-term efficacy, and durability with respect to aneurysm sac regression, target vessel patency, overall mortality, and reintervention rates. Long-term results are still awaited, until then, the rate of graft limb occlusion is of concern and should be further investigated, especially in case of particularly complex aortic anatomies.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.avsg.2017.03.171 | DOI Listing |
Can J Cardiol
January 2025
Division of Cardiac Surgery, Rady Faculty of Health Sciences, University of Manitoba, Winnipeg, MB. Electronic address:
The volume of transcatheter aortic valve implantation (TAVI) for treatment of isolated aortic stenosis has far surpassed surgical aortic valve replacement (SAVR). There has been a consequent increase in TAVI explantation, now the fastest growing cardiac surgical procedure. Transcatheter heart valve explantation can be technically complex, with higher perioperative morbidity and mortality than routine SAVR or valve-in-valve TAVI.
View Article and Find Full Text PDFJ Thorac Cardiovasc Surg
January 2025
University of Maryland School of Medicine, Division of Cardiothoracic Surgery. Electronic address:
Objective: Over 30% of patients presenting with acute type A aortic dissection (ATAAD) are considered high - risk or inoperable. This study aims to investigate the early and mid-term outcomes of complex endovascular aortic repair of aortic root, ascending aorta, and aortic arch among patients with ATAAD.
Methods: From January 2018 to January 2023, 29 patients who were considered high risk for open operation underwent endovascular aortic repair.
Clin Imaging
January 2025
Institute of Clinical sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden; Dept of Pediatric Radiology, The Queen Silvia Children's Hospital, Region Västra Götaland, Sahlgrenska University Hospital, Gothenburg, Sweden.
Background: Congenital heart diseases (CHDs) are common birth defects. This work presents over four years of clinical experience of 4D flow cardiovascular magnetic resonance (CMR), highlighting its value for pediatric CHD.
Methods: Children with various CHD diagnoses (n = 298) were examined on a 1.
Indian J Thorac Cardiovasc Surg
February 2025
Department of Cardiology, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, 230001 Anhui China.
Purpose: Acute aortic dissection is a serious cardiovascular emergency with a high mortality rate. Its pathogenesis is complex and remains unclear. This study aimed to assess the connection between the levels of genetically predicted circulating metabolites and the risk of aortic dissection.
View Article and Find Full Text PDFJACC Case Rep
January 2025
Chinese Institutes for Medical Research and Anzhen Hospital, Capital Medical University, Beijing, China.
Although open repair remains the mainstream treatment for aortic arch dissection, its surgical complexity and perioperative complications are significant. We developed a novel stentgraft system for less-invasive endovascular aortic arch repair. We successfully performed a total percutaneous transfemoral endovascular repair of aortic arch dissection using a novel off-the-shelf endograft system.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!