Cell line studies and analytical measurements of three paclitaxel complex variations.

Bioorg Med Chem Lett

ICR Facility, National High Field Magnet Lab, Tallahassee, FL 32310, United States.

Published: June 2017

The copper(II) cation, sucrose, and hydroxychloroquine were complexed with the chemotherapy agent paclitaxel and studied for medicinal activity. Data (GI, LD) from single dose and five dose National Cancer Institute sixty cell line panels are presented. Analytical measurements of different complexes were made using Nuclear Magnetic Resonance (H NMR), Matrix Assisted Laser Desorption Ionization-Time of Flight-Mass Spectrometry (MALDI-TOF-MS) and Fourier Transform-Ion Cyclotron Resonance (FT-ICR). Molecular modeling is utilized to better understand the impact that species could have on physical parameters associated with Lipinski's Rule of Five, such as logP and TPSA. On average, Cu(II) and hydroxychloroquine decreased GI values, while sucrose increased GI values of paclitaxel.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bmcl.2017.04.070DOI Listing

Publication Analysis

Top Keywords

analytical measurements
8
cell studies
4
studies analytical
4
measurements three
4
three paclitaxel
4
paclitaxel complex
4
complex variations
4
variations copperii
4
copperii cation
4
cation sucrose
4

Similar Publications

The exposome is the measure of all the exposures of an individual in a lifetime and how those exposures relate to health. Exposomics is the emerging field of research to measure and study the totality of the exposome. Exposomics can assist with molecular medicine by furthering our understanding of how the exposome influences cellular and molecular processes such as gene expression, epigenetic modifications, metabolic pathways, and immune responses.

View Article and Find Full Text PDF

Understanding whether risk preference represents a stable, coherent trait is central to efforts aimed at explaining, predicting and preventing risk-related behaviours. We help characterize the nature of the construct by adopting a systematic review and individual participant data meta-analytic approach to summarize the temporal stability of 358 risk preference measures (33 panels, 57 samples, 579,114 respondents). Our findings reveal noteworthy heterogeneity across and within measure categories (propensity, frequency and behaviour), domains (for example, investment, occupational and alcohol consumption) and sample characteristics (for example, age).

View Article and Find Full Text PDF

In the present digital scenario, the explosion of Internet of Things (IoT) devices makes massive volumes of high-dimensional data, presenting significant data and privacy security challenges. As IoT networks enlarge, certifying sensitive data privacy while still employing data analytics authority is vital. In the period of big data, statistical learning has seen fast progressions in methodological practical and innovation applications.

View Article and Find Full Text PDF

Simulation-based approaches for setting indirect outcome-based analytical performance specifications (APS) predominantly involve test repetition through analytical reruns or resampling. These methodologies assess the agreement between original and simulated measurement results, determining the APS corresponding to pre-established performance thresholds. For APS related to imprecision and bias, both analytical performance characteristics (APCs) are typically considered in simulations, whereas for APS regarding measurement uncertainty, bias is excluded in alignment with traceability standards.

View Article and Find Full Text PDF

Comparability of the LDH measurement and analysis based on external quality assessment.

Clin Chim Acta

January 2025

Department of Clinical Laboratory, Beijing Chaoyang Hospital, The Third Clinical Medical College of Capital Medical University, Beijing Center for Clinical Laboratories, No. 8 Gongti South Road, Chaoyang District, Beijing 100020, PR China. Electronic address:

Background: Lactate dehydrogenase (LDH) is a critical enzyme widely used in clinical diagnostics. However, variations in measurement systems can lead to inconsistent results, potentially impacting clinical decision-making. This study aimed to evaluate the comparability of lactate dehydrogenase measurements by comparing routine methods with the IFCC reference method, and to analyze the standardization status of LDH testing through external quality assessment (EQA).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!