We tested the agreement of radiologists' rankings of different reconstructions of breast computed tomography images based on their diagnostic (classification) performance and on their subjective image quality assessments. We used 102 pathology proven cases (62 malignant, 40 benign), and an iterative image reconstruction (IIR) algorithm to obtain 24 reconstructions per case with different image appearances. Using image feature analysis, we selected 3 IIRs and 1 clinical reconstruction and 50 lesions. The reconstructions produced a range of image quality from smooth/low-noise to sharp/high-noise, which had a range in classifier performance corresponding to AUCs of 0.62 to 0.96. Six experienced Mammography Quality Standards Act (MQSA) radiologists rated the likelihood of malignancy for each lesion. We conducted an additional reader study with the same radiologists and a subset of 30 lesions. Radiologists ranked each reconstruction according to their preference. There was disagreement among the six radiologists on which reconstruction produced images with the highest diagnostic content, but they preferred the midsharp/noise image appearance over the others. However, the reconstruction they preferred most did not match with their performance. Due to these disagreements, it may be difficult to develop a single image-based model observer that is representative of a population of radiologists for this particular imaging task.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5414890PMC
http://dx.doi.org/10.1117/1.JMI.4.2.025502DOI Listing

Publication Analysis

Top Keywords

image-based model
8
image quality
8
radiologists
6
image
6
reconstruction
5
lack agreement
4
agreement radiologists
4
radiologists implications
4
implications image-based
4
model observers
4

Similar Publications

Malaria remains a global health concern, with 249 million cases and 608,000 deaths being reported by the WHO in 2022. Traditional diagnostic methods often struggle with inconsistent stain quality, lighting variations, and limited resources in endemic regions, making manual detection time-intensive and error-prone. This study introduces an automated system for analyzing Romanowsky-stained thick blood smears, focusing on image quality evaluation, leukocyte detection, and malaria parasite classification.

View Article and Find Full Text PDF

Background/objectives: In recent years, numerous studies have been published on determining the WHO grade of central nervous system (CNS) tumors using machine learning algorithms. These studies are usually based on magnetic resonance imaging (MRI) and sometimes also on positron emission tomography (PET) images. To date, however, there are virtually no corresponding studies based on routinely generated computed tomography (CT) images.

View Article and Find Full Text PDF

Solid-organ malignancies represent a significant disease burden and remain one of the leading causes of death globally. In the past few decades, the rapid evolution of imaging modalities has shifted the paradigm towards image-based precision medicine, especially in the care of patients with solid-organ malignancies. Metabolic tumor volume (MTV) is one such semi-quantitative parameter obtained from positron emission tomography (PET) imaging with F-fluorodeoxyglucose (FDG) that has been shown to have significant implications in the clinical oncology setting.

View Article and Find Full Text PDF

Brain imaging data is one of the primary predictors for assessing the risk of Alzheimer's disease (AD). This study aims to extract image-based features associated with the possibly right-censored time-to-event outcomes and to improve predictive performance. While the functional proportional hazards model is well-studied in the literature, these studies often do not consider the existence of patients who have a very low risk and are approximately insusceptible to AD.

View Article and Find Full Text PDF

Computational nuclear oncology for precision radiopharmaceutical therapy (RPT) is a new frontier for theranostic treatment personalization. A key strategy relies on the possibility to incorporate clinical, biomarker, image-based, and dosimetric information in theranostic digital twins (TDTs) of patients to move beyond a one-size-fits-all approach. The TDT framework enables treatment optimization by real-time monitoring of the real-world system, simulation of different treatment scenarios, and prediction of resulting treatment outcomes, as well as facilitating collaboration and knowledge sharing among health care professionals adopting a harmonized TDT.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!