Introduction: In younger patients, ceramic-on-ceramic (CoC) bearing surfaces are usually recommended for total hip replacement (THR) because of their low wear rate and longer expected functional life. Although technical advancements have reduced the risk of ceramic bearings fracture, this complication remains a major concern.
Case Description: We present the case of a 56-year-old patient undergoing 3 revision hip arthroplasties of the right hip due to ceramic liner fractures. Initial THR (2008) was performed with a CoC bearing, followed by liner fracture due to trauma a year later. The acetabular component and liner were replaced, with a minor incongruence between the old head and new insert. The 2nd ceramic insert fractured 3.5 years later, following minor trauma. Upon revision, the bearing surface was changed to metal-on-polyethylene (MoP). The performed retrieval analysis demonstrated stripe and rim wear, and evidence of adhesive wear. The patient was referred to us a month later, with a fistula on the lateral side of the hip, discharging black, petroleum-like liquid. Radiology showed well-fixed implants, no dislocation and no apparent polyethylene wear. Microbiological assessment of the discharge showed no infection. Intraoperatively massive metallosis was noticed, with stable acetabular and femoral components. The metal femoral head was heavily abraded, with almost 1% volumetric wear. Hematoxylin and eosin stained frozen tissue samples showed muscular and adipose tissue necrosis, while polarized light microscopy highlighted metal, polyethylene, and ceramic particles.
Conclusion: The present case is yet another report showing the adverse outcomes of using MoP bearings for revision after ceramic liner fracture in THR.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5428579 | PMC |
http://dx.doi.org/10.1097/MD.0000000000006687 | DOI Listing |
Cureus
December 2024
Orthopedic Surgery, Tri-County Orthopedics, Bridgewater, USA.
A 73-year-old female experienced an atraumatic fracture of a BIOLOX delta ceramic femoral head following uncomplicated right total hip arthroplasty using a ceramic-on-polyethylene bearing. The fracture occurred post-operatively, as revealed by radiography after the patient reported a clunking sensation and leg shortening. Revision surgery involved replacing the fractured head and liner with careful removal of ceramic debris.
View Article and Find Full Text PDFCureus
October 2024
Trauma and Orthopedics, Royal Orthopaedic Hospital, Birmingham, GBR.
Pseudotumors are a rare complication of total hip arthroplasty (THA), arising from local soft tissue reactions. These reactions can lead to painful joint effusions and prosthetic loosening, often necessitating revision surgery. Metal-on-metal and metal-on-polyethylene prostheses are particularly prone to this complication due to the accumulation of metal debris from prosthetic wear, which represents a significant drawback.
View Article and Find Full Text PDFPLoS Med
November 2024
University of Bristol Medical School, Translational Health Sciences, Musculoskeletal Research Unit, Bristol, United Kingdom.
Background: The risk of re-operation, otherwise known as revision, following primary hip replacement depends in part on the prosthesis implant materials used. Current performance evidences are based on a broad categorisation grouping together different materials with potentially varying revision risks. We investigated the revision rate of primary total hip replacement (THR) reported in the National Joint Registry by specific types of bearing surfaces used.
View Article and Find Full Text PDFJ Arthroplasty
October 2024
Department of Orthopedic Surgery, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, South Korea.
J Bone Joint Surg Am
December 2024
Department of Orthopaedic Surgery, Southern California Permanente Medical Group, Harbor City, California.
Background: The increased availability of dual-mobility acetabular constructs (DMCs) provides surgeons with a newer option to increase the effective femoral head size in revision total hip arthroplasty (rTHA). We sought to evaluate risks of re-revision and prosthetic dislocation following rTHA involving a DMC compared with other articulations.
Methods: A cohort study was conducted using data from a U.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!