Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Vascular access is essential for hemodialysis patients. The mature native arteriovenous fistula has been the preferred vascular access for hemodialysis, because it has greater longevity than synthetic grafts. However, once surgically created, fistulas often fail to develop (mature) into viable points of vascular access, requiring surgical or radiologic interventions before their use. Because maturation depends on vascular mechanics (e.g., distensibility and wall shear), we developed open-source ultrasound software to investigate these metrics clinically. We demonstrated in a single patient the ability of the software for consistent measurements from various locations within a cardiac cycle and between different cardiac cycles. We further assessed the ability of the software to identify changes in distensibility of a patient's fistula from 1 to 6 weeks postoperation. The routine frame rates of clinical machines demonstrated high fidelity tracking within cardiac cycles (coefficient of variation [CV] = 2.4% ± 0.011) and between cardiac cycles (CV = 2.4% ± 0.004). The distensibility of the patient's fistula from 1 to 6 weeks postoperation increased from 4% to 7% in the arterial inflow and from 3% to 4% in the postarterial anastomotic segment (PAAS). In contrast, the distensibility of the outflow vein decreased from 4% to 2%. These results corroborate that in addition to diameter changes, the mechanical properties of the vascular segments changed during fistula maturation. This demonstrates that our software-based approach may allow ultrasound-based mechanical measurements to become more accessible for wider clinical research.