Secondary limb lengthening after intercalary bone resection in pediatric patients is still challenging. After the resection, a free fibula autograft can be used to reconstruct the osseous gap. However, in particular in young pediatric patients, insufficient growth of the epiphyseal plate after transplantation may lead to a significant limb-length discrepancy (LLD). In this case, the autograft was used for limb lengthening. We report on the lengthening of a humerus regenerate after fibula autograft transplantation into a humeral defect in a pediatric/young adolescent patient. Because of LLD, she underwent callus distraction of the humerus regenerate after transplantation of a fibula autograft using a unilateral external fixator device. An 18-year-old female patient with status postintercalary proliferating chondroma resection (at the age of 7 years) required treatment for correction of a 13 cm humerus shortening. She reported no pain, had no functional limitations, and had a full range of motion of the shoulder and elbow joint. She complained about her short humerus and overall body scheme. A unilateral external fixator device for callus distraction was applied to the transplanted humerus regenerate after free fibula autograft transplantation. Bone lengthening was performed by distraction (2×0.5 mm/day). After 62 days and a lengthening of 6 cm in total, bone distraction was stopped mainly to avoid any complication. At this time, there was no limitation in the range of motion. No nerve palsy or other problems occurred at any time of the distraction. In pediatric patients, the transplantation of a fibula autograft is a well-established option to bridge an osseous gap after intercalary bone resection. This case report shows that even the humerus regenerate after fibula autograft transplantation has excellent potential for callotasis and bone remodeling and therefore bone lengthening in patients with LLD is an option even after transplantation of an autograft. This method provides a new therapeutic option for patients with LLD after fibula transplantation.

Download full-text PDF

Source
http://dx.doi.org/10.1097/BPB.0000000000000464DOI Listing

Publication Analysis

Top Keywords

fibula autograft
24
humerus regenerate
16
pediatric patients
12
autograft transplantation
12
transplantation
9
fibula
8
limb lengthening
8
intercalary bone
8
bone resection
8
free fibula
8

Similar Publications

Background And Objectives: For the planning of surgical procedures involving the bony reconstruction of the mandible, the autologous iliac crest graft, along with the fibula graft, has become established as a preferred donor region. While computer-assisted planning methods are increasingly gaining importance, the necessary preparation of geometric data based on CT imaging remains largely a manual process. The aim of this work was to develop and test a method for the automated segmentation of the iliac crest for subsequent reconstruction planning.

View Article and Find Full Text PDF

Collateral injuries are usually found in association with cruciate ligament tears. There are multiple techniques to reconstruct the collateral ligaments using autografts and allografts. Conventionally, interference screws are used to fix the graft on the femur, tibia, and fibula.

View Article and Find Full Text PDF

Introduction: surface sarcomas are a rare entity that need correct diagnosis to differentiate parosteal (cPOS), periosteal and the high grade surface osteosarcomas (HGSO). HGSO has malignant behavior similarities with osteosarcomas and wide resection is the key to a successful treatment.1 The Capanna and Hemi-Capanna reconstruction techniques have being developed in order to avoid amputation after an oncological resection, allowing structural support from an allograft and biological advantages from a vascularised autograft.

View Article and Find Full Text PDF

Purpose: Flexible flatfoot deformity is quite common among adolescents. This study aimed to report the preliminary results of calcaneal lengthening osteotomy using a fibular bone graft.

Methods: This single-center, retrospective study included 28 patients (28 feet) with symptomatic flexible flatfoot deformity.

View Article and Find Full Text PDF

Lower Limb Length and Body Weight are Surrogate Predictors of Peroneus Longus Autograft Diameter.

Indian J Orthop

November 2024

Present Address: Department of Orthopaedics and Sports Medicine, Fortis Mohali, Punjab, India.

Introduction: Graft diameters are essential in any ACL surgery, with diameters less than 8mm associated with higher revision rates. Peroneus longus (PL) grafts have garnered much attention recently due to ease of harvest and more reliable graft diameters. The present study aimed to study various anthropometric parameters associated with PL-graft diameters.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!