A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Purification of a polyclonal antibody against CD147 for ELISA using antigen‑immunoaffinity chromatography. | LitMetric

Purification of a polyclonal antibody against CD147 for ELISA using antigen‑immunoaffinity chromatography.

Mol Med Rep

Department of Cell Biology, National Translational Science Center for Molecular Medicine, Fourth Military Medical University, Xi'an, Shaanxi 710032, P.R. China.

Published: June 2017

The immunoglobulin superfamily member CD147 is a widely expressed glycoprotein that occurs in both a membrane‑spanning and soluble form. Sandwich ELISA is a powerful tool for analyzing soluble antigens. The aim of the present study was to obtain a highly specific polyclonal antibody against human CD147 that can be used for sandwich ELISA analysis. Expression of recombinant CD147 by a eukaryotic expression system was used to immunize rabbits to obtain antiserum. A highly specific polyclonal antibody that was able to detect soluble CD147 in sandwich ELISA was obtained by antigen‑immunoaffinity chromatography purification. The purity of rabbit anti‑CD147 polyclonal antibodies was ~99%, and ELISA analysis was able to determine the titer of the rabbit anti‑CD147 polyclonal antibodies at 1:512,000. The lowest concentration of the standard CD147 antigen that the sandwich ELISA was able to detect was 31.25 pg/ml. The sandwich ELISA system was composed of anti‑hepatoma HAb18 monoclonal antibodies and purified rabbit anti‑CD147 polyclonal antibodies. The present study demonstrated that antigen‑immunoaffinity chromatography may be a good technique for the purification of polyclonal antibodies, which may be used to detect antigen in sandwich ELISAs.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5436266PMC
http://dx.doi.org/10.3892/mmr.2017.6523DOI Listing

Publication Analysis

Top Keywords

sandwich elisa
20
polyclonal antibodies
16
polyclonal antibody
12
antigen‑immunoaffinity chromatography
12
rabbit anti‑cd147
12
anti‑cd147 polyclonal
12
purification polyclonal
8
elisa antigen‑immunoaffinity
8
highly specific
8
specific polyclonal
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!