A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Aortic Valve Annular Sizing: Intraoperative Assessment Versus Preoperative Multidetector Computed Tomography. | LitMetric

Aortic Valve Annular Sizing: Intraoperative Assessment Versus Preoperative Multidetector Computed Tomography.

Circ Cardiovasc Imaging

From the Division of Cardiothoracic Surgery, New York Presbyterian Hospital - College of Physicians and Surgeons of Columbia University, New York, NY (I.G., A.M., C.W., N.K., C.S.); Division of Thoracic Surgery, University Hospital of Zurich, Switzerland (L.C.G.); Division of Cardiology, New York Presbyterian Hospital - College of Physicians and Surgeons of Columbia University, NY (N.B., R.H., S.K., M.L., M.A.B., O.K.K.); Division of Cardiothoracic Surgery, Guys and St. Thomas Hospital Trust, London, United Kingdom (V.B.); and Department of Cardiothoracic Surgery, New York University, NY (M.W.).

Published: May 2017

Background: Appropriate valve sizing is critical in aortic valve replacement. We hypothesized that direct intraoperative valve sizing results in smaller aortic annular diameters compared with sizing based on systolic-phase multidetector computerized tomographic (MDCT) imaging.

Methods And Results: We retrospectively analyzed 78 patients undergoing surgical aortic valve replacement for severe aortic stenosis between 2012 and 2014 at our institution. Preoperative MDCT measurements of the aortic annulus served as basis for assignment to a theoretical surgical valve size, which was then (1) compared to the implanted valve size and (2) to a theoretical transcatheter aortic valve replacement valve size. To quantify the resulting differences, geometric orifice areas (GOA) were calculated. MDCT-based sizing produced the same valve size for n=34 patients (group CT-same), a larger valve with a 25% increased GOA in n=32 patients (group CT-Lg) and a smaller GOA by 22% in n=12 patients (group CT-Sm). On the basis of MDCT measurements, 41% of valves implanted were undersized. The comparison of intraoperative implanted to a theoretical transcatheter aortic valve replacement valve size resulted in GOAs 25% larger for patients in group CT-same, 40.6% larger in group CT-Lg and 14.6% larger in group CT-Sm.

Conclusions: Preoperative MDCT measurements differ substantially from direct intraoperative assessment of the aortic annulus. Implanted surgical aortic valve replacement valves were smaller relative to MDCT-based sizing in 41% of patients, and the potential GOA was between 25% and 40.6% larger if patients had undergone transcatheter aortic valve replacement.

Download full-text PDF

Source
http://dx.doi.org/10.1161/CIRCIMAGING.116.005968DOI Listing

Publication Analysis

Top Keywords

aortic valve
28
valve replacement
24
valve size
20
patients group
16
valve
14
mdct measurements
12
transcatheter aortic
12
aortic
11
intraoperative assessment
8
valve sizing
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!