Introduction: Liposuction is a popular surgical procedure. As in any surgery, there are risks and complications, especially when combined with fat injection. Case reports of fat embolism have described a possible explanation as the puncture and tear of gluteal vessels during the procedure, especially when a deep injection is planned.
Methods: A total of 10 dissections were performed in five fresh cadavers. Each buttocks was divided into four quadrants. We focused on the location where the gluteal vessels enter the muscle and the diameter of the vessels. Colorant at two different angles was injected (30° and 45°). We evaluated the relation of the colorant with the main vessels.
Results: We found two perforators per quadrant. The thickness of the gluteal muscle was 2.84 ± 1.54 cm. The area under the muscle where the superior gluteal vessels traverse the muscle was located 6.4 ± 1.54 cm from the intergluteal crease and 5.8 ± 1.13 cm from the superior border of the muscle. The inferior gluteal vessels were located 8.3 ± 1.39 cm from the intergluteal crease and 10 ± 2.24 cm from the superior border of the muscle. When we compared the fat injected at a 30° angle, the colorant stayed in the muscle. Using a 45° angle, the colorant was in contact with the superior gluteal artery and the sciatic nerve. No puncture or tear was observed in the vessels or the nerve.
Conclusions: The location where the vessels come in contact with the muscle, which can be considered for fat injection, were located in quadrants 1 and 3. A 30° angle allows for an injection into the muscle without passing into deeper structures, unlike a 45° injection angle.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1080/08941939.2017.1321703 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!