A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Cerebral Granulomatous Inflammation Secondary to Hydrophilic Polymer Embolization Following Thrombectomy. | LitMetric

BACKGROUND Given the recent completion of multiple trials demonstrating the benefit of endovascular mechanical thrombectomy for select patients with proximal large artery occlusive ischemic strokes, there has been a large increase in the performance of these procedures. In the context of increased thrombectomy performance, there have also been increased reports of rare occurrences of granulomatous inflammatory response to the hydrophilic polymer which coat many of these interventional devices. CASE REPORT A 59-year-old female presented with a complete occlusion of her right proximal middle cerebral artery (MCA) and imaging showed a large area of penumbra. Cerebral angiogram and mechanical thrombectomy were successfully performed with reversal of clinical symptoms. Eight months following her stroke, she developed progressive recurrence of left-sided neurological deficits. After extensive workup culminating in tissue sampling, she was found to have developed granulomatous inflammation surrounding microscopic embolization of hydrophilic polymer, which is used to coat many interventional devices such as wires and catheters. The patient responded both clinically and radiographically to anti-inflammatory steroid therapy. CONCLUSIONS Recognizing the significant potential morbidity of a large vessel ischemic stroke and the expanded use of endovascular interventions aimed at staving off this disability, there are emerging and at times indolent complications from the use of hydrophilic polymer coated wires and catheters. This rare and potentially under-recognized complication should be considered in the differential for any patient with new neurological findings following cerebral intervention, especially given the consideration that this appears to a treatable complication.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5434860PMC
http://dx.doi.org/10.12659/ajcr.902598DOI Listing

Publication Analysis

Top Keywords

hydrophilic polymer
16
granulomatous inflammation
8
mechanical thrombectomy
8
polymer coat
8
coat interventional
8
interventional devices
8
wires catheters
8
cerebral
4
cerebral granulomatous
4
inflammation secondary
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!