Background: The Aptima HCV Quant Dx assay (Aptima) is a real-time transcription-mediated amplification assay CE-approved for the diagnosis and monitoring of hepatitis C virus (HCV) infection.
Objective: Aptima's analytical performance was compared to the Abbott RealTime HCV assay (RealTime) in a clinical routine setting.
Study Design: Overall 295 clinical plasma samples (117 prospective/fresh; 178 retrospective/frozen) from HCV-infected patients were tested in Aptima and RealTime to determine concordance on qualitative and quantitative results. Linearity and precision at low viral loads (VLs; 0.8-3.3LogIU/mL) was tested using dilutions of the 5th WHO standard, in 10 and 20 replicates in the two assays, respectively. The ability to measure different HCV genotypes and accuracy were analyzed using the Seracare EQA panel.
Results: Inter-assay agreement for qualitative results (prospective samples) was 88% (kappa=0.78). For the 127 samples with quantitative results in both assays, Aptima yielded on average slightly higher values (by 0.24LogIU/mL; Bland-Altman method) than RealTime. Concordance between assay results was excellent (R=0.98). At low VLs (0.8-3.3LogIU/mL), Aptima demonstrated good linearity and precision, similar to RealTime. Aptima detected and accurately quantified all main HCV genotypes.
Conclusions: Aptima demonstrated excellent precision, linearity, and accuracy in all genotypes tested. Good concordance was observed between Aptima and RealTime assays in clinical samples. The performance of the Aptima assay, on the fully automated Panther platform, makes it an excellent candidate for the detection and monitoring of HCV RNA in plasma and serum samples.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jcv.2017.04.013 | DOI Listing |
Microbiol Spectr
January 2025
National Microbiology Laboratory Branch, Public Health Agency of Canada, Winnipeg, Manitoba, Canada.
Unlabelled: Nucleic acid amplification tests (NAATs) are the method of choice for diagnosis, but these strategies are susceptible to target site mutations. variants escaping detection with the Aptima Combo 2 (AC2) assay on the Hologic Panther instrument from 23S rRNA mutations have been reported in Nordic countries, England, Japan, and the United States. Given the potential for false negative results, this study investigated whether strains of with AC2 target site mutations were present in Canada.
View Article and Find Full Text PDFObjective: Dynamic measures of team adaptation based in team cognition theory and the measurement of real-time team cognition are developed. The present study examines the validity and context-specificity of this measurement framework for simulation-based team training.
Background: Teams adapt by reorganizing their coordination behavior to overcome challenges in dynamic environments.
Med Sci Sports Exerc
December 2024
Cardiovascular Institute, Hospital Clínic, University of Barcelona (IDIBAPS), August Pi i Sunyer Biomedical Research Institute, Barcelona, SPAIN.
Purpose: COVID-19 is an independent risk factor for cardiovascular disease. The aim of this study is to determine the burden, characteristics, and causes of sudden death in sport (SrSD) before and after the COVID-19 pandemic in the general population.
Methods: Retrospective observational study.
Diagn Microbiol Infect Dis
December 2024
Department of Clinical Microbiology, Copenhagen University Hospital, Hvidovre, Denmark.
The global strategy to eradicate Hepatitis B (HBV), Hepatitis C (HCV), and HIV by 2030 is critical due to their impact and challenges to healthcare systems. HCV is curable, but HBV and HIV are only suppressible, with a vaccine available solely for HBV. Innovative diagnostic methods are needed, especially for high-risk populations like people who inject drugs (PWID).
View Article and Find Full Text PDFJ Virol Methods
December 2024
Scottish HPV Reference Laboratory, NHS Lothian, Royal Infirmary of Edinburgh, Little France, Edinburgh EH16 4SA, United Kingdom; HPV Research Group, University of Edinburgh, Edinburgh EH16 4TJ, United Kingdom.
Background: Self-sampling is now a key component within HPV-based cervical screening programmes to engage individuals and enhance participation. As self-sampling is relatively new, information on the influence of pre-analytical parameters such as transit-temperature and time between sampling and testing on HPV test results requires detailed investigation.
Methods: FLOQSwabs® and Evalyn Brushes® were used to assess HPV and cellular stability over a 30-week period (0w,4w,12w,30w) at 4 °C, ambient, and 37 °C.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!