Perceived indoor air quality and its relationship to air pollutants in French dwellings.

Indoor Air

French Indoor Air Quality Observatory, Scientific and Technical Center for Building (CSTB), University of Paris-Est, Marne la Vallée Cedex 2, France.

Published: November 2017

Perception of indoor air quality (PIAQ) was evaluated in a nationwide survey of 567 French dwellings, and this survey was combined with measurements of gaseous and particulate matter (PM and PM ) indoor air pollutants and indoor climate parameters. The perception was assessed on a nine-grade scale by both the occupants of the dwellings and the inspectors who performed the measurements. The occupants perceived the air quality in their homes as more pleasant than the inspectors. The inspectors perceived the air quality as more unpleasant in dwellings in which the residents smoked indoors. Significant associations between PIAQ and indoor air pollutant concentrations were observed for both the inspectors and, to a lesser extent, the occupants. Introducing confounding parameters, such as building and personal characteristics, into a multivariate model suppressed most of the observed bivariate correlations and identified the tenure status of the occupants and their occupation as the parameters that most influenced their PIAQ. For the inspectors, perceived air quality was affected by the presence of smokers, the season, the type of ventilation, retrofitting, and the concentrations of acetaldehyde and acrolein.

Download full-text PDF

Source
http://dx.doi.org/10.1111/ina.12393DOI Listing

Publication Analysis

Top Keywords

air quality
20
indoor air
16
perceived air
12
air
8
air pollutants
8
french dwellings
8
inspectors perceived
8
quality
5
inspectors
5
perceived
4

Similar Publications

Ambient temperature and hospitalizations of children due to respiratory diseases in Cuiabá-MT, Brazil.

Cien Saude Colet

January 2025

Departamento de Química e Energia. Faculdade de Engenharia e Ciências, UNESP/Campus Guaratinguetá. Guaratinguetá SP Brasil.

This study evaluated the role of temperature and fine particulate matter in hospitalizations of children living in Cuiabá-MT, obtained from DATASUS, between 01/01/2016 and 12/31/2018. Daily concentrations of the pollutant fine particulate matter were estimated using the CAMS mathematical model, made available by CPTEC. Diagnoses of tracheitis and laryngitis, pneumonia, bronchitis, bronchiolitis and asthma were included.

View Article and Find Full Text PDF

This study aimed to evaluate the concentrations of sulfur dioxide (SO2) and nitrogen oxides (NOX) around the Qom (a province in Iran) combined cycle power plant in relation to seasonal variations and fuel type from December 2014 to May 2015. Passive sampling was used in three monitoring sites around the power plant to assess noncarcinogenic health risks associated with exposure to SO2 and NOX. Results showed the higher concentrations of NOX and SO2 in winter than in spring.

View Article and Find Full Text PDF

Integrating mobile monitoring data with street view images (SVIs) holds promise for predicting local air pollution. However, algorithms, sampling strategies, and image quality introduce extra errors due to a lack of reliable references that quantify their effects. To bridge this gap, we employed 314 taxis to monitor NO, NO, PM, and PM, and extracted features from ∼382,000 SVIs at multiple angles (0°, 90°, 180°, 270°) and buffer radii (100-500 m).

View Article and Find Full Text PDF

Industrialized swine facilities adversely affect the health and well-being of Eastern North Carolina residents in the U.S. and are an issue of environmental racism.

View Article and Find Full Text PDF

Telomere Length and Symptoms of Attention Deficit and Hyperactivity Disorder in Children at 6-12 Years.

J Atten Disord

January 2025

Occupational Therapy Research Group (InTeO, Investigación en Terapia Ocupacional), Department of Surgery and Pathology, Miguel Hernandez University, Alicante, Spain.

Objective: To explore the association between telomere length (TL) and attention deficit hyperactivity disorder (ADHD) symptoms in children at 6-12 years.

Method: Data from 1,759 children belonging to the HELIX project cohorts and the Asturias, Gipuzkoa and Valencia cohorts of INMA project were included. TL was determined by blood sample using a PCR protocol.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!