The fast and effective neutralization of the mustard-gas simulant 2-chloroethyl ethyl sulfide (CEES) using a simple and portable continuous flow device is reported. Neutralization takes place through a fully selective sulfoxidation by a stable source of hydrogen peroxide (alcoholic solution of urea-H O adduct/MeSO H freshly prepared). The reaction progress can be monitored with an in-line benchtop NMR spectrometer, allowing a real-time adjustment of reaction conditions. Inherent features of millireactors, that is, perfect control of mixing, heat and reaction time, allowed the neutralization of 25 g of pure CEES within 46 minutes in a 21.5 mL millireactor (t =3.9 minutes). This device, which relies on affordable and nontoxic reagents, fits into a suitcase, and can be deployed by police/military forces directly on the attack site.