Background: Joint angle data from healthy subjects are necessary as baseline information.
Objective: To analyze the problems of patients who struggle with activities of daily living (ADL) due to restricted range of motion and to provide ADL guidance based on objective data.
Method: An electromagnetic three-dimensional tracking system (FASTRAK) was used to quantify the hip, knee, and ankle angles of the dominant leg of 26 healthy adults as they performed 22 ADLs related to dressing, using the toilet, bathing, picking up objects, and crouching. For each ADL, the maximum angle was averaged across the 26 subjects. Mean angles of adduction/abduction and internal/external rotation during maximum hip flexion were also measured.
Results: The largest mean maximum angle was 101° for hip flexion (trunk rotation during crouching), 17° for hip adduction (putting on shoes), and 149° for knee flexion (trunk rotation during crouching). Analysis of adduction/abduction and internal/external rotation angles during maximum hip flexion showed the largest angle of adduction when putting on shoes, and the largest angle of internal rotation with trunk rotation during crouching.
Conclusions: ADLs such as crouching and putting on pants showed larger joint angles than walking, climbing stairs, and standing up. Results obtained from this study can provide important objective data for ADL guidance for total hip arthroplasty and femoroacetabular impingement patients.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5537477 | PMC |
http://dx.doi.org/10.1016/j.bjpt.2017.03.012 | DOI Listing |
Acta Orthop Traumatol Turc
December 2024
Department of Orthopedics and Traumatology, Ege University School of Medicine, Izmir, Türkiye.
Objective: This study aimed to compare preoperative and postoperative measures in haemophiliacs who had simultaneous total hip and knee arthroplasties.
Methods: A retrospective database search identified five patients with severe factor 8 deficiencies who underwent simultaneous hip and knee joint replacement surgery between 2002-2018. Preoperative and postoperative evaluations included Harris Hip Score (HHS), Knee Society Score (KSS), Knee Injury and Osteoarthritis Outcome Score (KOOS), range of motion, flexion contracture (FC), Visual Analog Scale (VAS), hip-knee angle, and leg length discrepancy.
Int Orthop
January 2025
University of Lille, 42 rue Paul Duez, 59000, Lille, Nord, France.
Purpose: This study reports the relationship between posterior cruciate ligament (PCL) retention vs resection and soft tissue laxity and balance throughout flexion using a robotically controlled ligament tensioner.
Methods: 55 robotic-assisted TKAs (Total knee arthroplasty) were retrospectively reviewe. The robotic ligament tensioner collected laxity data both before and after PCL resection.
J Orthop Surg Res
January 2025
Department of Industrial Engineering, Alma Mater Studiorum-University of Bologna, Bologna, Italy.
Background: Transfemoral osseointegrated prostheses, like other uncemented prostheses experience the risk of aseptic loosening and post-operative periprosthetic fractures, with an incidence between 3% and 30%. To date, however, osseointegrated off-the-shelf prostheses are manufactured in a limited number of sizes, and some patients do not meet the strict eligibility criteria of commercial devices. A customized osseointegrated stem was developed and a pre-clinical in vitro investigation of the stem was performed, to evaluate its biomechanical performance.
View Article and Find Full Text PDFClin Rheumatol
January 2025
Department of Nephrorheumatology, Beijing Jishuitan Hospital Guizhou Hospital, Beijing, China.
Hip involvement is a common condition in about one-third of patients with axial spondyloarthritis (axSpA). We assessed the incidence of possible factors that predispose patients to limited flexion after total hip arthroplasty (THA) for the treatment of axSpA. We retrospectively reviewed 516 patients with axSpA (759 hips) who underwent THA.
View Article and Find Full Text PDFJ Ren Nutr
January 2025
Department of Nursing and Physiotherapy, Universidad Cardenal Herrera-CEU, CEU Universities, C/ Santiago Ramón y Cajal s/n 46115, Alfara del Patriarca, Valencia, Spain.
Objective: The aim was to assess the intra and inter-rater reliability of the handheld dynamometry testing of lower limb muscles during hemodialysis.
Methods: This is a cross-sectional study including subjects undertaking hemodialysis for at least 3 months. Handheld dynamometer measurements of hip and ankle muscle strength (N) were registered on 4 different occasions, 2 trials by raters A and 2 by raters B, to evaluate the intra and inter-rater reliability.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!