A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A Quality Improvement Approach to Standardization and Sustainability of the Hand-off Process. | LitMetric

There is mounting evidence that communication and hand-off failures are a root cause of two-thirds of sentinel events in hospitals. Several studies have shown that non-standardized hand-offs have yielded poor patient outcomes and adverse events. At Stony Brook University Hospital, there were numerous reported adverse events related to poor hand-off during the transfer of patient responsibility from one resident caregiver to the next. A resident-conducted root cause analysis identified lack of a standardized hand-off process and formal training on safe and efficient hand-off among caregivers as key contributing factors. This quality improvement project used the PDSA methodology to test the use of a standardized method, the IPASS mnemonic, and compare it to our conventional hand-off method in our internal medicine residency program. The main goals of this study were to test the feasibility and effectiveness of a standardized I- PASS hand-off and to create a robust sustainability model that includes 1) integration of I-PASS handoff in the Electronic Medical Record (EMR), 2) direct observation of the hand-off process by faculty and senior residents, and 3) surveillance and reporting of hand-off compliance scores. Compared to hand-off with a conventional method, the use of the I-PASS method resulted in significantly fewer reported adverse events (χ2=4.8, df=1, p=0.04). I-PASS was successfully integrated into our EMR system and residents were mandated to use this as the sole method of hand-off. An EMR audit conducted six months after implementation revealed poor compliance, which ultimately led to the creation of a sustainability model that improved overall compliance from 60% to 100%.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5387931PMC
http://dx.doi.org/10.1136/bmjquality.u222156.w8291DOI Listing

Publication Analysis

Top Keywords

hand-off process
12
adverse events
12
hand-off
11
quality improvement
8
reported adverse
8
sustainability model
8
method
5
improvement approach
4
approach standardization
4
standardization sustainability
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!