AI Article Synopsis

Article Abstract

A wideband tunable optoelectronic oscillator (OEO) based on the deamplification of stimulated Brillouin scattering (SBS) is proposed and experimentally demonstrated. A tunable single passband microwave photonic filter (MPF) utilizing phase modulation and SBS deamplification is used to realize the tunability of the OEO. Theoretical analysis of the MPF and phase noise performance of the OEO are presented. The frequency response of the MPF is determined by the + 1st sideband attenuation due to SBS deamplification and phase shift difference between the two sidebands due to chromatic dispersion and SBS. The close-in (< 1 MHz) phase noise of the proposed OEO is shown to be dominated by the laser frequency noise via phase shift of SBS. The conversion of the laser frequency noise to the close-in phase noise of the proposed OEO is effectively reduced compared with the OEO based on amplification by SBS. Tunable 7 to 40 GHz signals are experimentally obtained. The single-sideband (SSB) phase noise at 10 kHz offset is -128 dBc/Hz for 10.30 GHz signal. Compared with the OEO based on SBS amplification, the proposed OEO can achieve a phase noise performance improvement beyond 20 dB at 10 kHz offset. The maximum frequency and power drifts at 10.69 GHz are within 1 ppm and 1.4 dB during 1000 seconds, respectively. To achieve better close-in phase noise performance, lower frequency noise laser and higher pump power are preferred. The experimental results agree well with the theoretical models.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.25.010287DOI Listing

Publication Analysis

Top Keywords

phase noise
24
oeo based
12
noise performance
12
proposed oeo
12
frequency noise
12
phase
9
noise
9
wideband tunable
8
tunable optoelectronic
8
optoelectronic oscillator
8

Similar Publications

Purpose: The aim of the work is to develop a cascaded diffusion-based super-resolution model for low-resolution (LR) MR tagging acquisitions, which is integrated with parallel imaging to achieve highly accelerated MR tagging while enhancing the tag grid quality of low-resolution images.

Methods: We introduced TagGen, a diffusion-based conditional generative model that uses low-resolution MR tagging images as guidance to generate corresponding high-resolution tagging images. The model was developed on 50 patients with long-axis-view, high-resolution tagging acquisitions.

View Article and Find Full Text PDF

Purpose: Pulmonary MRI faces challenges due to low proton density, rapid transverse magnetization decay, and cardiac and respiratory motion. The fermat-looped orthogonally encoded trajectories (FLORET) sequence addresses these issues with high sampling efficiency, strong signal, and motion robustness, but has not yet been applied to phase-resolved functional lung (PREFUL) MRI-a contrast-free method for assessing pulmonary ventilation during free breathing. This study aims to develop a reconstruction pipeline for FLORET UTE, enhancing spatial resolution for three-dimensional (3D) PREFUL ventilation analysis.

View Article and Find Full Text PDF

Near-Field Clutter Mitigation in Speckle Tracking Echocardiography.

Ultrasound Med Biol

January 2025

Department of Electrical and Electronic Engineering, The University of Hong Kong, Hong Kong; Biomedical Engineering Programme, The University of Hong Kong, Hong Kong. Electronic address:

Objective: Near-field (NF) clutter filters are critical for unveiling true myocardial structure and dynamics. Randomized singular value decomposition (rSVD) stands out for its proven computational efficiency and robustness. This study investigates the effect of rSVD-based NF clutter filtering on myocardial motion estimation.

View Article and Find Full Text PDF

Motion-Compensated Multishot Pancreatic Diffusion-Weighted Imaging With Deep Learning-Based Denoising.

Invest Radiol

January 2025

From the Department of Radiology, Stanford University, Stanford, CA (K.W., M.J.M., A.M.L., A.B.S., A.J.H., D.B.E., R.L.B.); Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA (K.W.); GE HealthCare, Houston, TX (X.W.); GE HealthCare, Boston, MA (A.G.); and GE HealthCare, Menlo Park, CA (P.L.).

Objectives: Pancreatic diffusion-weighted imaging (DWI) has numerous clinical applications, but conventional single-shot methods suffer from off resonance-induced artifacts like distortion and blurring while cardiovascular motion-induced phase inconsistency leads to quantitative errors and signal loss, limiting its utility. Multishot DWI (msDWI) offers reduced image distortion and blurring relative to single-shot methods but increases sensitivity to motion artifacts. Motion-compensated diffusion-encoding gradients (MCGs) reduce motion artifacts and could improve motion robustness of msDWI but come with the cost of extended echo time, further reducing signal.

View Article and Find Full Text PDF

Significance: The precise identification and preservation of functional brain areas during neurosurgery are crucial for optimizing surgical outcomes and minimizing postoperative deficits. Intraoperative imaging plays a vital role in this context, offering insights that guide surgeons in protecting critical cortical regions.

Aim: We aim to evaluate and compare the efficacy of intraoperative thermal imaging (ITI) and intraoperative optical imaging (IOI) in detecting the primary somatosensory cortex, providing a detailed assessment of their potential integration into surgical practice.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!