New treatment modalities in radiotherapy (RT) enable delivery of highly conformal dose distributions in patients. This creates a need for precise dose verification in three dimensions (3D). A radiochromic silicone-based 3D dosimetry system has recently been developed. Such a dosimeter can be used for dose verification in deformed geometries, which requires knowledge of the dosimeter's mechanical properties. In this study we have characterized the dosimeter's elastic behaviour under tensile and compressive stress. In addition, the dose response under strain was determined. It was found that the dosimeter behaved as an incompressible hyperelastic material with a non-linear stress/strain curve and with no observable hysteresis or plastic deformation even at high strains. The volume was found to be constant within a 2% margin at deformations up to 60%. Furthermore, it was observed that the dosimeter returned to its original geometry within a 2% margin when irradiated under stress, and that the change in optical density per centimeter was constant regardless of the strain during irradiation. In conclusion, we have shown that this radiochromic silicone-based dosimeter's mechanical properties make it a viable candidate for dose verification in deformable 3D geometries.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6560/aa70cdDOI Listing

Publication Analysis

Top Keywords

mechanical properties
12
radiochromic silicone-based
12
dose verification
12
dosimeter's mechanical
8
dose
5
determining mechanical
4
properties radiochromic
4
dosimeter
4
silicone-based dosimeter
4
dosimeter treatment
4

Similar Publications

Background: To investigate the antibiofilm effect and mechanism of the silver nanowire (AgNW)-modified glass ionomer cement (GIC) against multi-species oral biofilm, and to examine the mechanical and biochemical properties of this novel GIC material.

Methods: Conventional GIC was incorporated with different concentrations of AgNW and silver nanoparticles (AgNP). Multi-species biofilms of Streptococcus mutans, Streptococcus sobrinus, Lactobacillus fermentum, and Lactobacillus rhamnosus were cultured for 72 h on GIC specimens.

View Article and Find Full Text PDF

Research on flexible strain sensors has grown rapidly and is widely applied in the fields of soft robotics, body motion detection, wearable sensors, health monitoring, and sports. In this study, MXene was successfully synthesized in powder form and combined with multi-walled carbon nanotube (MWCNT) to develop MWCNT@MXene conductive network-based flexible strain sensors with silicone rubber (SR) substrate. Combining MWCNTs with MXene as a conductive material has been shown to significantly improve the sensor performance, due to MXene's high conductivity properties that strengthen the MWCNT conductive pathway, increase sensitivity, and improve sensor stability.

View Article and Find Full Text PDF

Cubic silicon-carbide crystals (3C-SiC), known for their high thermal conductivity and in-plane stress, hold significant promise for the development of high-quality (Q) mechanical oscillators. We reveal degeneracy-breaking phenomena in 3C-phase crystalline silicon-carbide membrane and present high-Q mechanical modes in pairs or clusters. The 3C-SiC material demonstrates excellent microwave compatibility with superconducting circuits.

View Article and Find Full Text PDF

Understanding the mechanics linking cortical folding and brain connectivity is crucial for both healthy and abnormal brain development. Despite the importance of this relationship, existing models fail to explain how growing axon bundles navigate the stress field within a folding brain or how this bidirectional and dynamic interaction shapes the resulting surface morphologies and connectivity patterns. Here, we propose the concept of "axon reorientation" and formulate a mechanical model to uncover the dynamic multiscale mechanics of the linkages between cortical folding and connectivity development.

View Article and Find Full Text PDF

Thermal-Sensitive Artificial Ionic Skin with Environmental Stability and Self-Healing Property.

ACS Appl Mater Interfaces

January 2025

Key Laboratory of Organic Optoelectronics and Molecular Engineering and Laboratory of Flexible Electronics Technology, Department of Chemistry, Tsinghua University, Beijing 100084, P. R. China.

Wearable temperature-sensitive electronic skin enables robots to rapidly detect environmental changes and respond intelligently, thereby reducing temperature-related mechanical failures. Additionally, this temperature-sensitive skin can measure and record the temperature of external objects, broadening its potential applications in the medical field. In this study, we designed a thermally sensitive artificial ionic skin using ionic liquids (ILs) as solvents and carbon nanotubes (CNTs) as thermally conductive fillers.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!