A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Experience With Nocturnal Hemodialysis. | LitMetric

Experience With Nocturnal Hemodialysis.

Home Hemodial Int (1997)

The Wellesley Central Hospital, Toronto, Ontario, Canada.

Published: January 1997

In order to provide a highly efficient, long-duration form of hemodialysis, we developed nocturnal hemodialysis. Patients were dialyzed nightly at home for 8 - 10 hours, 6 - 7 nights/week. We kept the dialysate flow at 100 mL/min and the blood flow at 250 - 300 mL/min. Patients were monitored remotely from the hospital through a computer connection. An internal jugular line was used as an access. We have trained 12 patients over 30 months and have accumulated 160 patient-months worth of data. The patients tolerated the dialysis very well and slept through the night. There was a significant improvement in their sense of well-being. Nightly Kt/V was 0.99. Weekly removal of phosphate was two times as high and β -microglobulin four times as high as conventional hemodialysis. All patients have discontinued their phosphate binders and have increased their dietary phosphate and protein intake. Hypertension was controlled with fewer medications, and erythropoietin dosages decreased. Complications were infrequent and included catheter occlusion and infections. Reusing the dialyzers decreased the cost of the treatment to levels similar to continuous ambulatory peritoneal dialysis. Nocturnal hemodialysis represents a viable dialysis modality that combines high quality, low cost, and excellent tolerance.

Download full-text PDF

Source
http://dx.doi.org/10.1111/hdi.1997.1.1.32DOI Listing

Publication Analysis

Top Keywords

nocturnal hemodialysis
12
hemodialysis patients
8
times high
8
hemodialysis
5
patients
5
experience nocturnal
4
hemodialysis order
4
order provide
4
provide highly
4
highly efficient
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!