Introduction: Atrial fibrillation (AF) is often associated with heart failure. Several studies have demonstrated that resumption of sinus rhythm (SR) improves cardiac output in the long-term. Aims of this study were to evaluate the acute variations of left ventricular (LV) performance, following successful external cardioversion (ECV) of persistent AF using longitudinal strain (LSt) analysis, and the influence of inflammation.

Materials And Methods: We enrolled 48 patients with AF (age: 73 ± 12 years, men: 83.3%). A standard transthoracic echocardiographic evaluation was performed before the procedure and 6 h later; this included the analysis of LV endocardial peak LSt, a measure of myocardial deformation. In the last 32 patients, plasma concentration of interleukin-6 (IL-6) was also determined.

Results: Restoration of SR led to the decrease of heart rate (HR) (74 ± 21 vs 64 ± 10 bpm, < 0.001) and LV end-systolic volume (30 ± 16 vs 27 ± 17 mL/m, = 0.001), and to the increase of LV end-diastolic volume (LVEDV) (56 ± 20 vs 60 ± 21 mL/m, = 0.036) and ejection fraction (EF) (48 ± 10 vs 57 ± 11%, < 0.001). Peak LSt improved in 43 (89.6%) patients (-12.9 ± 3.3 vs -18.0 ± 4.7%, < 0.001). Multivariate analysis ( = 0.729, < 0.001) showed that strain changes were directly correlated with basal HR and the appearance of atrial mechanical activity and inversely correlated with corrected thyroid dysfunction, LVEDV and the presence of a permanent pacemaker. Higher levels of IL-6 negatively affected LV performance improvement.

Conclusions: Effective ECV of AF determines a significant and fast improvement of LV performance, which is readily captured by LSt analysis. Inflammatory status may impact the response to SR restoration.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5353402PMC
http://dx.doi.org/10.4103/2211-4122.131987DOI Listing

Publication Analysis

Top Keywords

external cardioversion
8
atrial fibrillation
8
longitudinal strain
8
lst analysis
8
peak lst
8
analysis
5
0001
5
cardioversion atrial
4
fibrillation early
4
early improvement
4

Similar Publications

We present the case of a 64-year-old man who, during the implantation of an active-fixation leadless pacemaker (LP, Aveir VR, Abbott, USA), underwent several external defibrillation shocks up to 240 Joules, due to symptomatic sustained supraventricular tachycardia at 160 bpm. The shocks, delivered both before and after the screwing of the device in the low interventricular septum, did not cause any technical damage to the device, and no complications were observed. The device was then deployed successfully.

View Article and Find Full Text PDF

OHCA (out-of-hospital cardiac arrest) patients have improved neurological outcomes with public-access automated external defibrillator (PAD) use. However, the benefit of epinephrine administration after PAD use remains controversial. The purpose of the study was to investigate the impact of epinephrine administration on neurological outcomes in OHCA patients after PAD use.

View Article and Find Full Text PDF

Introduction: The implantable cardioverter defibrillator reduces mortality among patients with heart failure (HF) due to ischemic heart disease. Clinical trial data have called into question the benefit of an ICD in patients with HF due to nonischemic cardiomyopathy (NICM). We developed a risk stratification score for ventricular tachyarrhythmia (VTA) among patients with NICM receiving a primary prevention ICD.

View Article and Find Full Text PDF

Background: Following international guidelines, communities have deployed automated external defibrillators at train stations without substantive evidence.

Methods And Results: We geocoded public out-of-hospital cardiac arrests (OHCAs) (2016-2020), automated external defibrillators, and train stations. The stations were divided into the following groups according to passenger flow: 1 (0-499), 2 (500-4999), 3 (5000-9999), and 4 (>10 000) passengers per day.

View Article and Find Full Text PDF

Background: In patients with out-of-hospital cardiac arrest who present with an initial shockable rhythm, a longer delay to the first shock decreases the probability of survival, often attributed to cerebral damage. The mechanisms of this decreased survival have not yet been elucidated. Estimating the probability of successful defibrillation and other factors in relation to the time to first shock may guide prehospital care systems to implement policies that improve patient survival by decreasing time to first shock.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!