Numerical analysis of wide-field optical imaging with a sub-20 nm resolution based on a meta-sandwich structure.

Sci Rep

Key Laboratory of Spectral Imaging Technology, Xi'an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, No. 17, Xinxi Road, Xian, 710119, P. R. China.

Published: May 2017

Biological research requires wide-field optical imaging techniques with resolution down to the nanometer scale to study the biological process in a sub-cell or single molecular level. To meet this requirement, wide-field structured illumination method (WFSIM) has been extensively studied. The resolution of WFSIM is determined by the period of the optical interference pattern. However, in traditional WFSIM this period is diffraction limited so that pattern having periodicity smaller than 100 nm cannot be generated and as a result achieving an imaging resolution better than 50 nm is a great challenge. Here, we demonstrate a wide-field optical nanoimaging method based on a meta-sandwich structure (MSS) model. It is found that this structure can support standing wave surface plasmons interference pattern with a period of only 31 nm for 532 nm wavelength incident light. Furthermore, the potential application of the MSS for wide-field super-resolution imaging is discussed and the simulation results show an imaging resolution of sub-20 nm can be achieved. The demonstrated method paves a new route for the improvement of the wide field optical nanoimaging, which can be applied by biological researchers to study biological process conducted in cell membrane, such as mass transportation and others.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5431004PMC
http://dx.doi.org/10.1038/s41598-017-01521-wDOI Listing

Publication Analysis

Top Keywords

wide-field optical
12
optical imaging
8
based meta-sandwich
8
meta-sandwich structure
8
study biological
8
biological process
8
interference pattern
8
imaging resolution
8
optical nanoimaging
8
wide-field
5

Similar Publications

ABCA4 Deep Intronic Variants Contributed to Nearly Half of Unsolved Stargardt Cases With a Milder Phenotype.

Invest Ophthalmol Vis Sci

January 2025

State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-Sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangzhou, China.

Purpose: The purpose of this study was to investigate the contribution and natural progression of ABCA4 deep intronic variants (DIVs) among a Chinese Stargardt disease (STGD) cohort.

Methods: For unsolved STGD probands, DIVs in ABCA4 were detected by next-generation sequencing, and splicing effects were evaluated by in silico tools and validated through minigene experiments. Comprehensive ocular examinations, especially fundus changes, were carried out and analyzed.

View Article and Find Full Text PDF

Structured illumination microscopy (SIM) is a robust wide-field optical nanoscopy technique. Several approaches are implemented to improve SIM's resolution capability (∼2-fold). However, achieving a high resolution with a large field of view (FOV) is still challenging.

View Article and Find Full Text PDF

Laser communications (lasercom) can enable more efficient and higher bandwidth communications than conventional radio frequency (RF) systems, but requires more sophisticated pointing and tracking (PAT) systems to acquire and maintain links. Liquid lens arrays can provide compact, nonmechanical beam steering as an alternative to fast-steering mirrors and mechanical gimbals. An array of two liquid lenses offset in perpendicular axes along with a third on-axis lens in the array are used for beam steering and divergence control, respectively.

View Article and Find Full Text PDF

Specimen-induced aberrations limit the penetration depth of standard optical imaging techniques in vivo, mainly due to the propagation of high NA beams in a non-homogenous medium. Overcoming these limitations requires complex optical imaging systems and techniques. Implantable high NA micro-optics can be a solution to tissue induced spherical aberrations, but in order to be implanted, they need to have reduced complexity, offering a lower surface to the host immune reaction.

View Article and Find Full Text PDF

Background: The aim of the study was to investigate the quantitative differences between severe stage 3 and stage 4A retinopathy of prematurity (ROP) by evaluating the pre-treatment fundus photographs.

Methods: Thirty-three eyes with clinical diagnosed as severe stage 3 were classified as severe stage 3 group. Twenty-two eyes with retinal detachment without foveal involvement were classified as stage 4A group.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!