OBJECTIVE Robot-guided pedicle screw placement is an established technique for the placement of pedicle screws. However, most studies have focused on degenerative disease. In this paper, the authors focus on metastatic spinal disease, which is associated with osteolysis. The associated lack of dense bone may potentially affect the automatic recognition accuracy of radiography-based surgical assistance systems. The aim of the present study is to compare the accuracy of the SpineAssist robot system with conventional fluoroscopy-guided pedicle screw placement for thoracolumbar metastatic spinal disease. METHODS Seventy patients with metastatic spinal disease who required instrumentation were included in this retrospective matched-cohort study. All 70 patients underwent surgery performed by the same team of experienced surgeons. The decision to use robot-assisted or fluoroscopy-guided pedicle screw placement was based the availability of the robot system. In patients who underwent surgery with robot guidance, pedicle screws were inserted after preoperative planning and intraoperative fluoroscopic matching. In the "conventional" group, anatomical landmarks and anteroposterior and lateral fluoroscopy guided placement of the pedicle screws. The primary outcome measure was the accuracy of screw placement on the Gertzbein-Robbins scale. Grades A and B (< 2-mm pedicle breach) were considered clinically acceptable, and all other grades indicated misplacement. Secondary outcome measures included an intergroup comparison of direction of screw misplacement, surgical site infection, and radiation exposure. RESULTS A total of 406 screws were placed at 206 levels. Sixty-one (29.6%) surgically treated levels were in the upper thoracic spine (T1-6), 74 (35.9%) were in the lower thoracic spine, and the remaining 71 (34.4%) were in the lumbosacral region. In the robot-assisted group (Group I; n = 35, 192 screws), trajectories were Grade A or B in 162 (84.4%) of screws. The misplacement rate was 15.6% (30 of 192 screws). In the conventional group (Group II; n = 35, 214 screws), 83.6% (179 of 214) of screw trajectories were acceptable, with a misplacement rate of 16.4% (35 of 214). There was no difference in screw accuracy between the groups (chi-square, 2-tailed Fisher's exact, p = 0.89). One screw misplacement in the fluoroscopy group required a second surgery (0.5%), but no revisions were required in the robot group. There was no difference in surgical site infections between the 2 groups (Group I, 5 patients [14.3%]; Group II, 8 patients [22.9%]) or in the duration of surgery between the 2 groups (Group I, 226.1 ± 78.8 minutes; Group II, 264.1 ± 124.3 minutes; p = 0.13). There was also no difference in radiation time between the groups (Group I, 138.2 ± 73.0 seconds; Group II, 126.5 ± 95.6 seconds; p = 0.61), but the radiation intensity was higher in the robot group (Group I, 2.8 ± 0.2 mAs; Group II, 2.0 ± 0.6 mAs; p < 0.01). CONCLUSIONS Pedicle screw placement for metastatic disease in the thoracolumbar spine can be performed effectively and safely using robot-guided assistance. Based on this retrospective analysis, accuracy, radiation time, and postoperative infection rates are comparable to those of the conventional technique.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3171/2017.3.FOCUS1710 | DOI Listing |
Musculoskelet Surg
January 2025
Department of Trauma and Orthopaedic Surgery, Barts Health NHS Trust, Royal London Hospital, London, E11BB, England.
3D-printed (3DP) drill guides have demonstrated significant potential to accurately guide pedicle screw insertion in spinal surgery. However, their role in the upper cervical spine is not well established. This review aimed to compare the efficacy and safety of 3DP drill guides to the conventional fluoroscopic-guided free-hand technique for pedicle screw insertion in the upper cervical spine.
View Article and Find Full Text PDFSpine Deform
January 2025
Pediatrics and Neurosurgery, Cedars Sinai Medical Center, Los Angeles, CA, USA.
Introduction: Congenital lumbar kyphosis is present in about 15% of patients with myelomeningocele. Worsening of deformity with complications such as chronic skin ulcers and bone exposure is common. In patients under 8 years of age, treatment becomes even more challenging: in addition to resecting the apex of the kyphotic deformity, we should ideally stabilize the spine with fixation methods that do not interrupt the growth of the rib cage, associated with the challenging pelvic fixation in this population.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Orthopedic Surgery, Chang Gung Memorial Hospital, No. 5, Fuxing St., Guishan Dist, Linkou, Taoyuan, 33305, Taiwan.
Objective: To investigate the predictive ability of the MRI-based vertebral bone quality (VBQ) score for pedicle screw loosening following instrumented transforaminal lumbar interbody fusion (TLIF).
Methods: Data from patients who have received one or two-level instrumented TLIF from February 2014 to March 2015 were retrospectively collected. Pedicle screw loosening was diagnosed when the radiolucent zone around the screw exceeded 1 mm in plain radiographs.
Neuromodulation
January 2025
Division of Gastroenterology and Hepatology, University of Michigan School of Medicine, Ann Arbor, MI, USA. Electronic address:
Objectives: Gastrointestinal (GI) disturbance is a frequent complication in patients with thoracolumbar vertebral fracture (TVF). Transcutaneous electrical acustimulation (TEA) has been reported to effectively accelerate postoperative GI function recovery after abdominal surgery. This study aimed to investigate the effects of TEA on postoperative recovery and the associated mechanisms.
View Article and Find Full Text PDFGlobal Spine J
January 2025
Department of Orthopaedics, University Clinic Heidelberg, Heidelberg, Germany.
Study Design: Retrospective Cohort Study.
Objectives: Flexibility radiographs such as traction or bending radiographs are essential in preoperative imaging to assess for curve flexibility and to estimate the amount of operative correction in order to determine the type and length of instrumentation in growth-accompanying scoliosis treatment. Both traction and bending radiographs are controversially discussed in the literature.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!