Objective: The objective of this study is to evaluate the ability of spleen volume, blood flow, and an index incorporating multiple measures to predict cirrhosis-associated hypersplenism.

Materials And Methods: A total of 39 patients (14 women and 25 men; mean [± SD] age, 52 ± 10 years) with cirrhosis and sequelae of portal hypertension underwent 4D flow MRI and anatomic 3-T MRI performed before and after contrast administration. Unenhanced 4D flow MRI was used to assess abdominal hemodynamics, and splenic volumes were measured on T1-weighted gradient-recalled echo MRI. Relationships among demographic characteristics, blood component counts, splenic volume, arterial flow, venous flow, and the percentage of shunted portal flow were assessed in 29 consecutive patients (i.e., the derivation group), to develop a splenic flow index. This index was assessed along with splenic volume and blood flow alone in 10 additional consecutive patients (i.e., the validation group) via ROC curve analysis, to identify platelet counts of less than 50 × 10 cells/μL, leukocyte counts of less than 3.0 × 10 cells/μL, or both.

Results: In the derivation cohort (platelet count, 129 ± 76 × 10 cells/μL), splenic volume, arterial flow, venous flow, and the percentage of shunted portal flow were inversely correlated with platelet counts (ρ = -0.68, -0.68, -0.56, and -0.36, respectively; p < 0.05). Adding splenic volume to arterial flow and the product of venous flow and the percentage of shunted portal flow indexed to the body surface area yielded superior correlations with platelet counts, leukocyte counts, and the degree of severity of hypersplenism (ρ = -0.75, -0.48, and -0.75, respectively; p ≤ 0.001) and predicted severe hypersplenism (sensitivity, 100%; specificity, 100%) in the validation cohort (platelet count, 93 ± 71 × 10 cells/μL).

Conclusion: A splenic flow index that incorporates both splenic volume and blood flow is a better indicator of hypersplenism than is splenic volume alone.

Download full-text PDF

Source
http://dx.doi.org/10.2214/AJR.16.17620DOI Listing

Publication Analysis

Top Keywords

splenic volume
24
flow
18
splenic flow
12
volume blood
12
blood flow
12
volume arterial
12
arterial flow
12
venous flow
12
flow percentage
12
percentage shunted
12

Similar Publications

Evaluation of Lyso-Gb1 as a biomarker for Gaucher disease treatment outcomes using data from the Gaucher Outcome Survey.

Orphanet J Rare Dis

January 2025

Department of Gastroenterology, Hepatology and Infectious Diseases, University Hospital, Heinrich- Heine University, Düsseldorf, Germany.

Background: Patients with Gaucher disease (GD) require continual monitoring; however, lack of specific disease biomarkers was a significant challenge in the past. Glucosylsphingosine (lyso-Gb1) has been shown to be a reliable, key, specific, and sensitive biomarker for diagnosis, prognosis, and treatment response in clinical studies of patients with GD. We evaluated the change in lyso-Gb1 concentration over time following enzyme replacement therapy in patients with confirmed GD using real-world data from the Gaucher Outcome Survey disease registry.

View Article and Find Full Text PDF

Sex-based variations in breath-holding: oxygen storage and diving response among non-divers.

Front Physiol

January 2025

Department of Health Sciences, Environmental Physiology Group, Mid Sweden University, Östersund, Sweden.

Breath-hold diving performances are typically better in men than in women. However, it is still being determined if there are differences in the physiological responses to breath-holding between the sexes. We conducted a study comparing the maximum breath-hold duration, heart rate (HR) reduction, peripheral oxygen saturation (SpO), and spleen volume and contraction in 37 men and 44 women, all of whom had no prior breath-holding experience.

View Article and Find Full Text PDF

Integration of artificial intelligence (AI) into radiology practice can create opportunities to improve diagnostic accuracy, workflow efficiency, and patient outcomes. Integration demands the ability to seamlessly incorporate AI-derived measurements into radiology reports. Common data elements (CDEs) define standardized, interoperable units of information.

View Article and Find Full Text PDF

Angiotensin II (Ang II) is the most active peptide hormone produced by the renin-angiotensin system (RAS). Genetic deletion of genes that ultimately restrict Ang II formation has been shown to result in marked anemia in mice. In this study, adult mice with a genetic deletion of the RAS precursor protein angiotensinogen (Agt-KO) were used.

View Article and Find Full Text PDF

: Accurate and reproducible spleen volume measurements are essential for assessing treatment response and disease progression in myelofibrosis. This study evaluates techniques for measuring spleen volume on abdominal MRI. : In 20 patients with bone marrow biopsy-proven myelofibrosis, 5 observers independently measured spleen volume on 3 abdominal MRI pulse sequences, 3D-spoiled gradient echo T1, axial single-shot fast spin echo (SSFSE) T2, and coronal SSFSE T2, using ellipsoidal approximation, manual contouring, and 3D nnU-Net model-assisted contouring comparing coefficients of variation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!