Wearable lower limb haptic feedback device for retraining Foot Progression Angle and Step Width.

Gait Posture

Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand; Dept of Engineering Science, University of Auckland, Auckland, New Zealand.

Published: June 2017

Technological developments in the last decade have enabled the integration of sensors and actuators into wearable devices for gait interventions to slow the progression of knee osteoarthritis. Wearable haptic gait retraining is one area which has seen promising results for informing modifications of gait parameters for reducing knee adduction moments (KAM) during walking. Two gait parameters which can be easily adjusted to influence KAM include foot progression angle (FPA) and step width (SW). The purpose of this study was to: (1) determine whether a custom haptic ankle bracelet using binary vibrotactile and tactile apparent movement feedback could retrain ten healthy subjects to walk with a modified FPA and SW within a short training session with 80% accuracy; and (2) whether there was a difference between the number of steps required to complete the retraining task based on the two feedback schemes being tested. Retraining multiple gait parameters using a single device was a novel aspect of this work and we found that nine out of ten subjects were able to retrain their gait using the ankle bracelet in both feedback schemes to within 2° and 39mm of target FPA and SW respectively. We also found no difference in the number steps required for completion between the two schemes (p>0.05). Future research will investigate the device performance with patients with knee osteoarthritis and the effective change in KAM by modifying a combination of FPA and SW.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.gaitpost.2017.04.028DOI Listing

Publication Analysis

Top Keywords

gait parameters
12
foot progression
8
progression angle
8
step width
8
knee osteoarthritis
8
ankle bracelet
8
difference number
8
number steps
8
steps required
8
feedback schemes
8

Similar Publications

A Comprehensive Review of Vision-Based Sensor Systems for Human Gait Analysis.

Sensors (Basel)

January 2025

Centre for Automation and Robotics (CAR UPM-CSIC), Escuela Técnica Superior de Ingeniería y Diseño Industrial (ETSIDI), Universidad Politécnica de Madrid, Ronda de Valencia 3, 28012 Madrid, Spain.

Analysis of the human gait represents a fundamental area of investigation within the broader domains of biomechanics, clinical research, and numerous other interdisciplinary fields. The progression of visual sensor technology and machine learning algorithms has enabled substantial developments in the creation of human gait analysis systems. This paper presents a comprehensive review of the advancements and recent findings in the field of vision-based human gait analysis systems over the past five years, with a special emphasis on the role of vision sensors, machine learning algorithms, and technological innovations.

View Article and Find Full Text PDF

Clinical motion analysis plays an important role in the diagnosis and treatment of mobility-limiting diseases. Within this assessment, relative (point-to-point) tracking of extremities could benefit from increased accuracy. Given the limitations of current wearable sensor technology, supplementary spatial data such as distance estimates could provide added value.

View Article and Find Full Text PDF

This study aimed to assess the intraday reliability of markerless gait analysis using an RGB-D camera versus a traditional three-dimensional motion analysis (3DMA) system with and without a simulated walking assistant. Gait assessments were conducted on 20 healthy adults walking on a treadmill with a focus on spatiotemporal parameters gathered using the RGB-D camera and 3DMA system. The intraday reliability of the RGB-D camera was evaluated using intraclass correlation coefficients (ICC 1, 1), while its consistency with the 3DMA system was determined using ICC (2, 1).

View Article and Find Full Text PDF

Parkinson's disease (PD) is characterized by a slow, short-stepping, shuffling gait pattern caused by a combination of motor control limitations due to a reduction in dopaminergic neurons. Gait disorders are indicators of global health, cognitive status, and risk of falls and increase with disease progression. Therefore, the use of quantitative information on the gait mechanisms of PD patients is a promising approach, particularly for monitoring gait disorders and potentially informing therapeutic interventions, though it is not yet a well-established tool for early diagnosis or direct assessment of disease progression.

View Article and Find Full Text PDF

Clinical Whole-Body Gait Characterization Using a Single RGB-D Sensor.

Sensors (Basel)

January 2025

German Center for Vertigo and Balance Disorders (DSGZ), LMU University Hospital, LMU Munich, 81377 Munich, Germany.

Instrumented gait analysis is widely used in clinical settings for the early detection of neurological disorders, monitoring disease progression, and evaluating fall risk. However, the gold-standard marker-based 3D motion analysis is limited by high time and personnel demands. Advances in computer vision now enable markerless whole-body tracking with high accuracy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!