AI Article Synopsis

  • Quantifying the knee's mechanical environment is essential for improving rehabilitation and surgical approaches, but current computational models mainly represent healthy conditions and fall short for pathological states.
  • The study aimed to develop specimen-specific finite element models for analyzing natural knee mechanics in both intact and ACL-deficient conditions using cadaveric specimens during simulated gait.
  • Results revealed significant differences in joint mechanics between intact and ACL-deficient states, including variability in ligament involvement and altered knee motion, which underscores the importance of tailored models for surgical planning.

Article Abstract

Quantifying the mechanical environment at the knee is crucial for developing successful rehabilitation and surgical protocols. Computational models have been developed to complement in vitro studies, but are typically created to represent healthy conditions, and may not be useful in modeling pathology and repair. Thus, the objective of this study was to create finite element (FE) models of the natural knee, including specimen-specific tibiofemoral (TF) and patellofemoral (PF) soft tissue structures, and to evaluate joint mechanics in intact and ACL-deficient conditions. Simulated gait in a whole joint knee simulator was performed on two cadaveric specimens in an intact state and subsequently repeated following ACL resection. Simulated gait was performed using motor-actuated quadriceps, and loads at the hip and ankle. Specimen-specific FE models of these experiments were developed in both intact and ACL-deficient states. Model simulations compared kinematics and loading of the experimental TF and PF joints, with average RMS differences [max] of 3.0° [8.2°] and 2.1° [8.4°] in rotations, and 1.7 [3.0] and 2.5 [5.1] mm in translations, for intact and ACL-deficient states, respectively. The timing of peak quadriceps force during stance and swing phase of gait was accurately replicated within 2° of knee flexion and with an average error of 16.7% across specimens and pathology. Ligament recruitment patterns were unique in each specimen; recruitment variability was likely influenced by variations in ligament attachment locations. ACL resections demonstrated contrasting joint mechanics in the two specimens with altered knee motion shown in one specimen (up to 5mm anterior tibial translation) while increased TF joint loading was shown in the other (up to 400N).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5541933PMC
http://dx.doi.org/10.1016/j.jbiomech.2017.04.008DOI Listing

Publication Analysis

Top Keywords

intact acl-deficient
12
acl-deficient conditions
8
joint mechanics
8
simulated gait
8
acl-deficient states
8
knee
6
combined measurement
4
measurement modeling
4
modeling specimen-specific
4
specimen-specific knee
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!