Background: Transcatheter tricuspid valve-in-valve implantation (TVIV) is an attractive yet under-explored alternative to redo valve surgery.
Objectives: To report the multicenter TVIV experience in Israel.
Methods: We approached multiple centers and collected data regarding seven TVIV cases.
Results: The study group comprised seven participants: five females and two males, with a mean age of 63 ± 12 years and EuroSCORE-II 13.6 ± 3.3%. Follow-up ranged from 3 to 21 months (mean 8 ± 6 months). All presented with advanced heart failure. The indication for valve intervention was a predominant tricuspid stenosis in three patients, significant tricuspid regurgitation in one and a mixture in three. Six procedures were conducted via a transfemoral approach and one by transatrial access. The Edwards SAPIENTM XT valve was used in four cases and the SAPIENTM 3 in three. Without pre-stenting/rapid pacing, all participants underwent successful valve implantation. Mean transvalvular gradient decreased from 11 ± 3 mmHg to 6 ± 3 mmHg (P = 0.003) and regurgitation decreased from moderate/severe (in four cases) to none/trace (in six of the seven cases). One patient remained severely symptomatic and died 3.5 months after the implantation. All others achieved a functional capacity improvement and amelioration of symptoms soon after the implantation, which persisted during follow-up.
Conclusions: TVIV may be a safe and effective strategy to treat carefully selected patients with degenerated bioprosthetic tricuspid valve at high operative risk.
Download full-text PDF |
Source |
---|
Cardiol Young
January 2025
Pediatric Cardiology, Stead Family Children's Hospital, University of Iowa, Iowa City, IA, USA.
Background: Despite patent ductus arteriosus closure in premature infants is a relatively fast procedure, it involves specific steps for equipment exchange and the use of a 4-Fr catheter, which may be large for tiny infants, potentially causing haemodynamic instability or tricuspid valve regurgitation.
Objectives: This study aims to describe the early experience with a new technique designed to simplify transcatheter patent ductus arteriosus closure in premature infants. It enables the closure using the KA micro plug device via a single microcatheter without equipment exchanges and contrast exposure.
Front Cardiovasc Med
January 2025
Clinic for General and Interventional Cardiology/Angiology, Herz- und Diabeteszentrum, NRW, Ruhr-Universität Bochum, Medizinische Fakultät OWL (Universität Bielefeld), Bad Oeynhausen, Germany.
Background: The tricuspid annular plane systolic excursion (TAPSE) assessed by echocardiography has failed in predicting outcomes in patients with severe tricuspid regurgitation (TR) undergoing transcatheter tricuspid valve intervention (TTVI). Considering the complex shape of the tricuspid annulus and right ventricle, as well as the difficult echocardiographic image acquisition of the right heart, cardiac computed tomography (CT) might be superior for the analysis of the annular excursion. Thus, this study aimed to analyze whether CT-captured TAPSE provides additional value in predicting outcomes after TTVI.
View Article and Find Full Text PDFEur Heart J
January 2025
Department of Cardiology, Keio University School of Medicine, Tokyo, Japan.
Background And Aims: The association between periprocedural change in tricuspid regurgitation (TR) and outcomes in patients undergoing mitral transcatheter edge-to-edge repair (M-TEER) is unclear. This study aimed to examine the prognostic value of TR before and after M-TEER.
Methods: Patients in the OCEAN-Mitral registry were divided into four groups according to baseline and post-procedure echocardiographic assessments: no TR/no TR (no TR), no TR/significant TR (new-onset TR), significant TR/no TR (normalized TR), and significant TR/significant TR (residual TR) (all represents before/after M-TEER).
Pacing Clin Electrophysiol
January 2025
Second Division of Cardiology, Cardiac-Thoracic and Vascular Department, University Hospital of Pisa, Pisa, Italy.
This case details the successful implantation of a leadless pacemaker following the extraction of transvenous leads in a 72-year-old female patient with a complex cardiovascular history. The patient had undergone a series of cardiac interventions, including a recent percutaneous tricuspid valve repair with a metal clip implant due to severe regurgitation. After presenting with an infection at the pacemaker site, methicillin-resistant Staphylococcus hominis was identified, necessitating the removal of the entire pacing system.
View Article and Find Full Text PDFRev Cardiovasc Med
January 2025
Cardiovascular Department IRCCS (Istituto di Ricerca e Cura a Carattere Scientifico) Humanitas Research Hospital, 20089 Rozzano, Milan, Italy.
Tricuspid regurgitation (TR) is a potentially lethal condition and represents a significant clinical challenge both for clinical and interventional cardiologists. Traditionally managed medically and surgically, transcatheter therapies are now an emerging option, especially in patients with prohibitive surgical risk due to age or comorbidities. Transcatheter tricuspid valve replacement (TTVR) is emerging as a potential solution for patients suffering from TR with positive clinical data supporting its use in a wide range of anatomies and clinical settings.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!