Background: Endoscopic cubital tunnel release has been proposed as an alternative to open in situ release. However, it is difficult to analyze outcomes after endoscopic release, as only a few small case series exist.
Methods: The electronic databases of PubMed (1960-June 2014) were systematically screened for studies related to endoscopic cubital tunnel release or open in situ cubital tunnel release. Baseline characteristics, clinical scores, and complication rates were abstracted. The binary outcome was defined as rate of excellent/good response versus fair/poor. Complications were recorded into 3 categories: wound problems, persistent ulnar nerve symptoms, and other.
Results: We included 8 articles that reported the clinical outcomes after surgical intervention including a total of 494 patients (344 endoscopic, 150 open in situ). The pooled rate of excellent/good was 92.0% (88.8%-95.2%) for endoscopic and 82.7% (76.15%-89.2%) for open. We identified 18 articles that detailed complications including a total of 1108 patients (691 endoscopic, 417 open). The 4 articles that listed complication rates for both endoscopic and open techniques were analyzed and showed a pooled odds ratio of 0.280 (95% confidence interval, 0.125-0.625), indicating that endoscopic patients have reduced odds of complications.
Conclusions: The results of this systematic review suggest that there is a difference in clinical outcomes between the open in situ and endoscopic cubital tunnel release, with the endoscopic technique being superior in regard to both complication rates along with patient satisfaction.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5480665 | PMC |
http://dx.doi.org/10.1177/1558944716662018 | DOI Listing |
PLoS One
January 2025
Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, Songpa-gu, Seoul, Republic of Korea.
Objective: Cubital tunnel syndrome is a common peripheral neuropathy of the upper extremity. Anterior transposition of the ulnar nerve is an established surgical treatment option for this condition. This study aimed to introduce a novel musculofascial lengthening technique that uses only a portion of the flexor-pronator muscle mass for submuscular anterior transposition of the ulnar nerve and investigate its clinical outcomes.
View Article and Find Full Text PDFPlast Surg (Oakv)
February 2025
Division of Plastic Surgery, Department of Surgery, McMaster University, Hamilton, Canada.
It is unknown whether early mobilization after cubital tunnel decompression improves functional outcomes without increasing complication risks. This systematic review aims to evaluate the effectiveness of early mobilization compared to delayed mobilization of the elbow after ulnar nerve decompression. Randomized controlled trials (RCTs) and observational studies comparing adults who received early mobilization or late mobilization were included.
View Article and Find Full Text PDFBiomed Phys Eng Express
January 2025
Children's Hospital of Eastern Switzerland, Claudiusstrasse 6, St.Gallen, 9006, SWITZERLAND.
Mapping the myomagnetic field of a straight and easily accessible muscle after electrical stimulation using triaxial optically pumped magnetometers (OPMs) to assess potential benefits for magnetomyography (MMG). Approach: Six triaxial OPMs were arranged in two rows with three sensors each along the abductor digiti minimi (ADM) muscle. The upper row of sensors was inclined by 45° with respect to the lower row and all sensors were aligned closely to the skin surface without direct contact.
View Article and Find Full Text PDFSmall Methods
January 2025
School of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
Flexible tactile sensors have received significant attention for use in wearable applications such as robotics, human-machine interfaces, and health monitoring. However, conventional tactile sensors face challenges in accurately measuring pressure because vertical deformation is induced by Poisson's ratio in situations where lateral strain is applied. This study shows a strain-insensitive flexible tactile sensor array without the crosstalk effect using a highly stretchable mesh.
View Article and Find Full Text PDFJ Orthop Res
January 2025
Department of Orthopaedic Surgery, Montefiore Einstein, Bronx, New York, USA.
Compression neuropathy is a prevalent medical condition, including common types such as carpal tunnel syndrome, cubital tunnel syndrome, sciatica, and many others. While the neurological consequences are well understood, the effects on bone properties and the potential downstream impact on fracture risk remain less clear. This study aimed to assess the influence of compressive neuropathy on bone properties using a rabbit model of sciatic nerve compression.