Clinical Feasibility of 3-Dimensional Magnetic Resonance Cholangiopancreatography Using Compressed Sensing: Comparison of Image Quality and Diagnostic Performance.

Invest Radiol

From the *Department of Radiology, and †College of Medicine, Seoul National University Hospital, Seoul, Republic of Korea; ‡Siemens Healthcare Gmbh, Erlangen, Germany; §Siemens Healthcare Korea; and ∥Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea.

Published: October 2017

AI Article Synopsis

  • The study aimed to compare the efficiency and image quality of fast 3D magnetic resonance cholangiopancreatography (MRCP) using compressed sensing (CS) against conventional navigator-triggered MRCP in evaluating bile and pancreatic duct conditions.
  • A total of 84 patients were reviewed, with fast MRCP showing significantly shorter acquisition times—CS-MRCP took about 3 minutes and 47 seconds compared to 7 minutes for conventional MRCP and just 16 seconds for breath-hold CS-MRCP.
  • Results indicated that CS-MRCP provided better image sharpness and visualization of the bile and pancreatic ducts but had lower background suppression compared to the conventional method.

Article Abstract

Objective: The aim of this study was to evaluate the clinical feasibility of fast 3-dimensional (3D) magnetic resonance cholangiopancreatography (MRCP) using compressed sensing (CS) in comparison with conventional navigator-triggered 3D-MRCP.

Materials And Methods: This retrospective study was approved by our institutional review board, and the requirement of informed consent was waived. A total of 84 patients (male-to-female ratio, 41:43; mean age, 47.3 ± 18.8 years) who underwent conventional 3D navigator-triggered T2-weighted MRCP using sampling perfection with application optimized contrasts (SPACE) and fast 3D MRCP using SPACE with high undersampling combined with CS reconstruction (CS SPACE; CS-MRCP) on a 3 T scanner were included. Among them, 28 patients additionally underwent 3D breath-hold CS-MRCP (BH-CS-MRCP) with 5.7% k-space sampling. Three board-certified radiologists then independently reviewed the examinations for bile duct and pancreatic duct visualization and overall image quality on a 5-point scale, and image sharpness and background suppression on a 4-point scale, with the higher score indicating better image quality. In addition, diagnostic performance for the detection of anatomic variation and diseases of the bile duct, and pancreatic disease were assessed on a per-patient basis in the subgroup of 28 patients who underwent conventional MRCP, CS-MRCP, and BH-CS-MRCP in the same manner.

Results: Mean acquisition times of conventional MRCP, CS-MRCP, and BH-CS-MRCP were 7 minutes (419.7 seconds), 3 minutes 47 seconds (227.0 seconds), and 16 seconds, respectively (P < 0.0001, in all comparisons). In all patients, CS-MRCP showed better image sharpness (3.54 ± 0.60 vs 3.37 ± 0.75, P = 0.04) and visualization of the common bile duct (4.55 ± 0.60 vs 4.39 ± 0.78, P = 0.034) and pancreatic duct (3.47 ± 1.22 vs 3.26 ± 1.32, P = 0.025), but lower background suppression (3.00 ± 0.54 vs 3.37 ± 0.58, P < 0.001) than conventional MRCP. Overall image quality was not significantly different between the 2 examinations (3.51 ± 0.95 vs 3.47 ± 1.09, P = 0.75). The number of indeterminate MRCP examinations for the anatomic variation and disease of the bile duct significantly decreased on CS-MRCP, from 16.7%-22.6% to 9.5%-11.9% and 8.4%-15.6% to 3.6%-8.4% in all readers (P = 0.003-0.03). In the 28 patients who underwent BH-CS-MRCP, better image quality was demonstrated than with conventional MRCP and CS-MRCP (4.10 ± 0.84 vs 3.44 ± 1.21 vs 3.50 ± 1.11, respectively, P = 0.002, 0.001). Sensitivities for detecting bile duct disease was 88.9% to 100% on both BH-CS-MRCP and conventional MRCP (P > 0.05), and for detecting pancreatic disease was 66.7% to 83.3% on BH-CS-MRCP and 50.0% to 72.2% on conventional MRCP (P = 0.002 in reader 1, 0.06-0.47 in readers 2-3).

Conclusions: Compressed sensing MRCP using incoherent undersampling combined with CS reconstruction provided comparable image quality to conventional MRCP while reducing the acquisition time to within a single breath-hold (16 seconds).

Download full-text PDF

Source
http://dx.doi.org/10.1097/RLI.0000000000000380DOI Listing

Publication Analysis

Top Keywords

conventional mrcp
28
image quality
24
bile duct
20
compressed sensing
12
mrcp
12
cs-mrcp bh-cs-mrcp
12
better image
12
mrcp cs-mrcp
12
conventional
9
clinical feasibility
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!