Objectives: To measure binaural benefit over the shadowed ear alone for young bilateral cochlear implant (CI) users. It was hypothesized that children who received bilateral CIs at a young age (<4 years), and had significant bilateral experience, would demonstrate lower detection thresholds for speech sounds in background noise in the bilateral CI over the unilateral CI condition when the added CI was ipsilateral to the noise source.
Design: Children receiving bilateral CIs at the Eye and Ear Hospital Clinic in Melbourne were invited to participate in a wider research project evaluating outcomes; those participating in the wider project who were bilaterally implanted by 4 years and were approximately 2 years postoperative were included in the present study. For 20 participants, detection signal to noise ratios (SNRs) were measured for speech presented from in front and noise from 90° in at least 3 of 4 device/noise conditions, namely left CI/noise right and right CI/noise left, plus bilateral CIs/noise right and bilateral CIs/noise left.
Results: As some participants could only complete testing in 3 conditions within the 1 test block, the unilateral versus bilateral comparison was performed for 1 CI (i.e., 1 noise direction) for 15 participants and for both CIs (i.e., noise left and noise right) for 5 participants. Group analysis indicated no significant difference in detection SNR between the unilateral and bilateral CI conditions when adding the left CI or right CI (for the overall group) or when adding the first or second CI (for the 15 participants with sequential bilateral CIs). Separate analyses indicated no significant difference in detection SNR between the unilateral and bilateral CI conditions for the majority of individuals; this occurred irrespective of whether the analysis indicated that the CI added in the bilateral condition was poorer-performing, better-performing, or not significantly different compared with the other CI. Four individuals demonstrated a significant improvement in the bilateral condition when the CI added in the bilateral condition was a better-performing (n = 1), poorer-performing (n = 2), or not significantly different CI (n = 1). There was no relationship between the detection SNR difference between each CI and the detection SNR difference between the unilateral and bilateral conditions.
Conclusions: The hypothesis of a lower detection SNR in the bilateral condition was not supported by the group results or by the results for the majority of individuals. For the 4 participants who did demonstrate benefit over the shadowed ear alone, that benefit cannot be separated from the potential benefit gained as a result of the CI added in the bilateral condition being the better-performing CI for 1 of the 4. Variation in outcomes could not be related to demographic factors for this group, which was relatively homogeneous for age at bilateral CI and experience; an older, more experienced group may demonstrate greater binaural benefit in these conditions. These results can be used during counseling for families regarding postoperative expectations for young children, especially in the first 2 years.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/AUD.0000000000000442 | DOI Listing |
J Otol
October 2024
Department of Otolaryngology Head and Neck Surgery, Chinese PLA General Hospital, Beijing, China.
The prevalence of unilateral deafness (SSD) or asymmetric hearing loss (AHL) among patients with hearing impairments ranges from 7.2% to 15.0%, indicating a relatively significant proportion.
View Article and Find Full Text PDFAm J Audiol
January 2025
Department of Otolaryngology, University of Utah, Salt Lake City.
Purpose: Unilateral cochlear implant (CI) recipients with limited hearing in the contralateral ear are deprived of the advantages of binaural hearing. To address speech recognition challenges arising from the head shadow effect, a contralateral routing of signal (CROS) device can be used; however, less is known of the broader impact of a CROS device on an individual's quality of life (QoL) or that of their frequent communication partners (FCPs). This preliminary study aimed to evaluate the impact of CROS on speech recognition in noise and its influence on the QoL of unilateral CI recipients and their FCPs.
View Article and Find Full Text PDFInt J Pediatr Otorhinolaryngol
December 2024
Division of Otology, Department of Otorhinolaryngology & Head and Neck Surgery, Linkou Chang Gung Memorial Hospital, Taoyuan, Taiwan; School of Medicine, Chang Gung University, Taoyuan, Taiwan. Electronic address:
Introduction: Despite the reported auditory deficits and developmental challenges in children with unilateral microtia and aural atresia (UMAA), there remains a lack of consensus on early intervention with bone conduction hearing aids (BCHAs) to restore binaural hearing due to the uncertain clinical benefits and intolerability of the conventional devices. Previous studies investigating the auditory benefits under binaural hearing condition were limited and demonstrated controversial opinions in heterogenous patient groups with various devices. Our study aimed to evaluate the audiological performance, including monoaural and binaural hearing, and subjective satisfaction of the ADHEAR system, a novel adhesive BCHA, in experienced pediatric users with UMAA.
View Article and Find Full Text PDFAppl Psychophysiol Biofeedback
December 2024
Integrative Wellbeing Institute (IWI), Windermere, FL, USA.
Brainwave Entrainment (BWE) is a noninvasive method of neuromodulation based on the principle that auditory or visual stimulation at a specific frequency can lead the brain's electrocortical activity to oscillate at the frequency of the external signal or its multiples. This phenomenon could be used to alter physiological and psychological states. Therefore, we conducted an integrative review to answer the question: "What are the observed benefits of BWE on human health and well-being?" We searched for studies published in the last ten years in the Directory of Open Access Journals (DOAJ), EMBASE, Virtual Health Library (BVS), PubMed, SciELO, and Cochrane Library databases in April 2024.
View Article and Find Full Text PDFEur J Neurosci
January 2025
Experimental Otorhinolaryngology, Department of Neurosciences, KU Leuven - University of Leuven, Leuven, Belgium.
Binaural unmasking is a remarkable phenomenon that it is substantially easier to detect a signal in noise when the interaural parameters of the signal are different from those of the noise - a useful mechanism in so-called cocktail party scenarios. In this study, we investigated the effect of binaural unmasking on neural tracking of the speech envelope. We measured EEG in 8 participants who listened to speech in noise at a fixed signal-to-noise ratio, in two conditions: one where speech and noise had the same interaural phase difference (both speech and noise having an opposite waveform across ears, SπNπ), and one where the interaural phase difference of the speech was different from that of the noise (only the speech having an opposite waveform across ears, SπN).