A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Feasibility, safety, and outcomes of a single-step endoscopic ultrasonography-guided drainage of pancreatic fluid collections without fluoroscopy using a novel electrocautery-enhanced lumen-apposing, self-expanding metal stent. | LitMetric

Background And Objectives: There are currently limited data available regarding the safety of endoscopic ultrasound (EUS)-guided drainage of pancreatic fluid collections (PFCs) using the lumen-apposing metal stent without fluoroscopic guidance. This study aims to evaluate clinical outcomes and safety of EUS-guided drainage of PFC using the electrocautery-enhanced lumen-apposing metal stents (EC-LAMSs) without fluoroscopic guidance.

Methods: We conducted a retrospective study on patients with symptomatic PFC who underwent EUS-guided drainage using EC-LAMS without fluoroscopy. All patients were followed clinically until resolution of their PFC. Technical success (successful placement of EC-LAMS), number of patients who achieved complete resolution of PFC without additional intervention and adverse events were noted.

Results: We evaluated 25 patients, including three with pancreatic pseudocysts and 22 with walled-off necrosis (WON). The etiology of the patient's pancreatitis was gallstones (42%), alcohol (27%), and other causes (31%). The mean cyst size was 82 mm (range, 60-170 mm). The indications for endoscopic drainage were abdominal pain, infected WON, or gastric outlet obstruction. Technical success with placement of the EC-LAMS was achieved in all 25 patients. There were no procedure-related complications. The mean patient follow-up was 7.8 months. PFCs resolved in 24 (96%) patients; the one failure was in a patient with WON. Stent occlusion was seen in one patient. There was a spontaneous migration of one stent into the enteral lumen after resolution of WONs. The EC-LAMS were successfully removed using a snare in all the remaining patients. The median number of endoscopy sessions to achieve PFCs resolution was 2 (range, 2-6).

Conclusions: Single-step EUS-guided drainage of PFCs without fluoroscopic guidance using the novel EC-LAMS is a safe and effective endoscopic technique for drainage of PFCs with excellent technical and clinical success rates and no complications. Due to its ease of use, EC-LAMS may simplify and streamline EUS-guided management of PFC and help in its widespread adoption as an alternative to surgery.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5418966PMC
http://dx.doi.org/10.4103/2303-9027.204814DOI Listing

Publication Analysis

Top Keywords

eus-guided drainage
16
drainage pancreatic
8
pancreatic fluid
8
fluid collections
8
electrocautery-enhanced lumen-apposing
8
metal stent
8
lumen-apposing metal
8
fluoroscopic guidance
8
resolution pfc
8
technical success
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!