Atherosclerotic plaques in the bifurcation of the carotid arteries can pose a significant health risk due to possible plaque rupture and subsequent stroke. The assessment of plaques, and evaluation of the risk they pose, can be performed with Black-Blood (BB) vessel wall magnetic resonance imaging. However, resolution at standard clinical field strengths (up to 3T) is limited, hampering reliable assessment and diagnosis. The aim of this study was to investigate the benefits of 7T MRI using a BB application that has been successful at clinical field strengths. Therefore, for BB imaging, each sequence was preceded with 'Delay Alternating with Nutation for Tailored Excitation' (DANTE) preparation pulses for blood signal suppression. A coil comprising a 4-channel Tx array was designed and built to provide the required excitation coverage for the DANTE train; and a 4-channel Rx array was constructed to target the carotid bifurcation. Human and phantom results showed satisfactory blood suppression and comparable SNR and CNR to 3T, therefore demonstrating the feasibility of the application at 7T. However, the imposed SAR restrictions led to long scan times and subsequent motion artifacts. Thus, more accurate local SAR supervision schemes are required which could lead to a further improvement of BB DANTE vessel wall imaging at 7T.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.mri.2017.04.011DOI Listing

Publication Analysis

Top Keywords

vessel wall
8
clinical field
8
field strengths
8
4-channel array
8
purpose-built neck
4
neck coil
4
coil black-blood
4
black-blood dante-prepared
4
dante-prepared carotid
4
carotid artery
4

Similar Publications

Development of Electrospinning Setup for Vascular Tissue-Engineering Application with Thick-Hierarchical Fiber Alignment.

Tissue Eng Regen Med

January 2025

College of Materials Science and Engineering, Hunan University, Changsha, 410072, People's Republic of China.

Background: Tissue engineering holds promise for vascular repair and regeneration by mimicking the extracellular matrix of blood vessels. However, achieving a functional and thick vascular wall with aligned fiber architecture by electrospinning remains a significant challenge.

Methods: A novel electrospinning setup was developed that utilizes an auxiliary electrode and a spring.

View Article and Find Full Text PDF

The intra-aortic balloon pump (IABP) is a widely-used mechanical circulatory support device that enhances hemodynamics in patients with heart conditions. Although the IABP is a common clinical tool, its effectiveness in enhancing outcomes for patients with acute myocardial infarction and cardiogenic shock remains disputed. This study aimed to assess the effectiveness of intra-aortic dual-balloon pump (IADBP) and its impact on aortic hemodynamics compared with an IABP.

View Article and Find Full Text PDF

Background: The cannulation of the internal jugular vein (IJV) is a frequent procedure in critically ill patients. According to the guidelines, real-time ultrasound navigation is recommended. Traditional techniques pose several disadvantages, such as suboptimal needle visualization.

View Article and Find Full Text PDF

A Novel Method for Hemorrhage Control During Laparoscopic Distal Pancreatectomy with Splenic Vessel Preservation: Triple Occlusion.

Ann Surg Oncol

January 2025

Division of Pancreatic Surgery, Department of General Surgery, West China Hospital, Sichuan University, Chengdu, Sichuan, China.

Introduction: Laparoscopic distal pancreatectomy (LDP) has the advantages of reduced blood loss, shorter hospital stays, and a better postoperative quality of life compared with open distal pancreatectomy (ODP). Meanwhile, spleen-preserving laparoscopic distal pancreatectomy is the preferred technique for low-grade malignant and benign tumors located in pancreatic body and tail, since it preserves the immune function of the spleen. The splenic-vessel-preserving (SVP) Kimura technique and splenic vessel resection Warshaw technique are the two primary procedures.

View Article and Find Full Text PDF

Background: Intracranial atherosclerotic stenosis is a leading cause of ischemic stroke and recurrent events due to plaque instability. High-resolution magnetic resonance imaging identifies plaque enhancement as a key marker of instability. This study evaluated the efficacy of combined high-intensity statins and proprotein convertase subtilisin/kexin type 9 inhibitors in plaque stabilization.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!