Background: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) diagnoses and stages mediastinal lymph node pathology. This retrospective study determined the relationship between EBUS-TBNA utility and non-small cell lung cancer (NSCLC) stage, lymph node size, and positron emission tomography (PET) standard uptake values (SUV), and the utility of neck ultrasound in bulky mediastinal disease.

Methods: Data of 284 consecutive patients who had undergone EBUS-TBNA was collected. Two hundred patients had suspected NSCLC, with 148 confirmed NSCLC cases. The diagnostic utility of EBUS-TBNA was determined according to NSCLC stage, EBUS lymph node size, PET SUV, use in distal metastases, and mutation testing. The utility of neck ultrasound for N3 disease was calculated in patients with bulky mediastinal disease.

Results: EBUS-TBNA was well tolerated with 97% sensitivity in distant metastatic disease, avoiding the need for distal metastases biopsy in 81% of cases. It had equivalent diagnostic accuracy in all NSCLC stages and in lymph nodes <10 mm, <20 mm or >20 mm (sensitivity >92% in all cases), with no mutation testing failures. EBUS-TBNA had 33% sensitivity in PET indolent (SUV < 4) nodes and 79% sensitivity in PET active nodes (SUV > 4). EBUS-TBNA diagnosed 12 cases of lymphoma without flow cytometry.

Conclusions: The use of EBUS-TBNA meant that distant metastatic biopsy was avoided in 81% of cases, performing well irrespective of cancer stage, node size, and facilitating mutation testing. Neck ultrasound failed to detect N3 disease in patients with bulky mediastinal disease. EBUS-TBNA had a sensitivity of 33% for metastases in PET negative nodes, highlighting PET limitations.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5494455PMC
http://dx.doi.org/10.1111/1759-7714.12438DOI Listing

Publication Analysis

Top Keywords

node size
16
lymph node
12
neck ultrasound
12
bulky mediastinal
12
mutation testing
12
ebus-tbna
9
endobronchial ultrasound-guided
8
needle aspiration
8
positron emission
8
emission tomography
8

Similar Publications

Objective: This retrospective study aimed to evaluate the predictive value of the preoperative dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) and diffusion-weighted imaging (DWI) findings of mass lesions for predicting sentinel lymph node (SLN) metastasis in early breast cancer.

Methods: A total of 310 patients with suspicious mass lesions detected in preoperative MRI who subsequently underwent surgery and SLN biopsy (SLNB) between September 2015 and September 2022 were analyzed. The relationship between DCE-MRI and DWI findings and SLNB positivity was analyzed.

View Article and Find Full Text PDF

Background: Aggressive digital papillary adenocarcinoma (ADPA) is a rare skin adnexal tumor with a predilection for the hand. The presentation, treatment, and outcomes of ADPA remain poorly defined due to the scarcity of reports and low-level evidence of published findings.

Methods: We performed a meta-analysis following Preferred Reporting Items for Systematic reviews and Meta-Analyses guidelines with the intent to provide hand surgeons a better understanding of the diagnosis and treatment of the disease.

View Article and Find Full Text PDF

Surgical Emergencies in Rectal Cancer: A Narrative Review.

J Clin Med

December 2024

General Surgery Department, Fondazione IRCCS Policlinico San Matteo, 27100 Pavia, Italy.

Colorectal cancer (CRC) is the third most diagnosed cancer worldwide and the second most common cause of cancer death. About 20% of patients diagnosed with rectal cancer present with emergency symptoms. Typical symptoms include acute bleeding, obstruction, and perforation.

View Article and Find Full Text PDF

Today, huge amounts of time series data are sensed continuously by AIoT devices, transmitted to edge nodes, and to data centers. It costs a lot of energy to transmit these data, store them, and process them. Data compression technologies are commonly used to reduce the data size and thus save energy.

View Article and Find Full Text PDF

Implantable Passive Sensors for Biomedical Applications.

Sensors (Basel)

December 2024

School of Electrical and Computer Engineering, National Technical University of Athens, 15772 Athens, Greece.

Article Synopsis
  • Implantable sensors are becoming popular for localized and continuous monitoring in medical settings, allowing for early detection and timely interventions.
  • There are two main types of implantable sensors: active, which have more advanced functionalities but require a power source, and passive, which don't need power and offer simpler, smaller designs.
  • This review focuses on passive sensor technologies, discussing their materials, detection methods, clinical applications, advantages over active sensors, and important considerations for their packaging and compatibility with the human body.
View Article and Find Full Text PDF