A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Do Medial Pivot Kinematics Correlate With Patient-Reported Outcomes After Total Knee Arthroplasty? | LitMetric

Do Medial Pivot Kinematics Correlate With Patient-Reported Outcomes After Total Knee Arthroplasty?

J Arthroplasty

Department of Orthopaedic Surgery, Indiana University School of Medicine, Indianapolis, Indiana; Indiana University Health Physicians Orthopedics & Sports Medicine, Indiana University Health Saxony Hospital, Fishers, Indiana.

Published: August 2017

Background: Many total knee arthroplasty (TKA) implants are designed to facilitate a medial pivot kinematic pattern. The purpose of this study was to determine whether intraoperative medial pivot kinematic patterns are associated with improved patient outcomes.

Methods: A retrospective review of consecutive primary TKAs was performed. Sensor-embedded tibial trials determined kinematic patterns intraoperatively. The center of rotation (COR) was identified from 0° to 90° and from 0° to terminal flexion, and designated medial-pivot or non-medial pivot based on accepted criteria. Patient-reported outcomes were measured preoperatively and at minimum one-year follow-up.

Results: The analysis cohort consisted of 141 TKAs. Mean age and median BMI were 63.7 years and 33.8 kg/m, respectively. Forty-percent of TKAs demonstrated a medial pivot kinematic pattern intraoperatively. A medial pivot pattern was more common with posterior cruciate-retaining (CR) and posterior cruciate-substituting/anterior lipped (CS) implants when compared to posterior stabilized (PS) TKAs (P ≤.0150). Regardless of bearing type, minimum one-year Knee Society scores and UCLA activity level did not significantly differ based on medial vs non-medial pivot patterns (P ≥.292). For patients with posterior cruciate-sacrificing implants, there were trends for greater median improvement in Knee Society objective (46 vs 31.5 points, P =.057) and satisfaction (23 vs 14 points, P =.067) scores in medial pivot knees.

Conclusion: A medial pivot pattern may not significantly govern clinical success after TKA based on intraoperative kinematics and modern outcome measures. Further research is warranted to determine if a particular kinematic pattern promotes optimal clinical outcomes.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.arth.2017.03.019DOI Listing

Publication Analysis

Top Keywords

medial pivot
28
pivot kinematic
12
kinematic pattern
12
medial
8
patient-reported outcomes
8
total knee
8
pivot
8
kinematic patterns
8
non-medial pivot
8
minimum one-year
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!