Pyrenyl carbon nanostructures for ultrasensitive measurements of formaldehyde in urine.

Anal Chim Acta

Department of Chemistry, Oklahoma State University, 107 Physical Sciences Building, Stillwater, OK 74078, USA. Electronic address:

Published: June 2017

Measurement of ultra-low (e.g., parts-per-billion) levels of small-molecule markers in body fluids (e.g., serum, urine, saliva) involves a considerable challenge in view of designing assay strategies with sensitivity and selectivity. Herein we report for the first time an amperometric nano-bioelectrode design that uniquely combines 1-pyrenebutyric acid units pi-pi stacked with carboxylated multiwalled carbon nanotubes on the surface of gold screen printed electrodes for covalent attachment of NAD dependent formaldehyde dehydrogenase (FDH). The designed enzyme bioelectrode offered 6 ppb formaldehyde detection in 10-times diluted urine with a wide dynamic range of 10 ppb to 10 ppm. Fourier transform infrared, Raman, and electrochemical impedance spectroscopic characterizations confirmed the successful design of the FDH bioelectrode. Flow injection analysis provided lower detection limit and greater affinity for formaldehyde (apparent K 9.6 ± 1.2 ppm) when compared with stirred solution method (apparent K 19.9 ± 4.6 ppm). Selectivity assays revealed that the bioelectrode was selective toward formaldehyde with a moderate cross-reactivity for acetaldehyde (∼25%) and negligible cross-reactivity toward propanaldehyde, acetone, methanol, and ethanol. Formaldehyde is an indoor pollutant, and studies have indicated neurotoxic characteristics and systemic toxic effects of this compound upon chronic and high doses of exposure. Moreover, reported chromatography and mass spectrometry methods identified elevated urine formaldehyde levels in patients with bladder cancer, dementia, and early stages of cognitive impairments compared to healthy people. Results demonstrate that pyrenyl carbon nanostructures-based FDH bioelectrode design represents novelty and simplicity for enzyme-selective electrochemical quantitation of small 30 Da formaldehyde. Broader applicability of the presented approach for other small-molecule markers is feasible that requires only the design of appropriate marker-specific enzyme systems or receptor molecules.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5443713PMC
http://dx.doi.org/10.1016/j.aca.2017.03.032DOI Listing

Publication Analysis

Top Keywords

pyrenyl carbon
8
formaldehyde
8
small-molecule markers
8
fdh bioelectrode
8
carbon nanostructures
4
nanostructures ultrasensitive
4
ultrasensitive measurements
4
measurements formaldehyde
4
urine
4
formaldehyde urine
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!