Immediate versus delayed postpartum insertion of contraceptive implant for contraception.

Cochrane Database Syst Rev

Department of Epidemiology and Biostatistics, Faculty of Public Health, Khon Kaen University, 123 Mitraparb Road, Amphur Muang, Khon Kaen, Thailand, 40002.

Published: April 2017

Background: The spacing of pregnancies has a positive impact on maternal and newborn health. The progestin contraceptive implant, which is a long-acting, reversible method of contraception, has a well-established low failure rate that is compatible with tubal sterilization. The standard provision of contraceptive methods on the first postpartum visit may put some women at risk of unintended pregnancy, either due to loss to follow-up or having sexual intercourse prior to receiving contraception. Therefore, the immediate administration of contraception prior to discharge from the hospital that has high efficacy may improve contraceptive prevalence and prevent unintended pregnancy.

Objectives: To compare the initiation rate, effectiveness, and side effects of immediate versus delayed postpartum insertion of implant for contraception.

Search Methods: We searched for eligible studies up to 28 October 2016 in the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, Embase, and POPLINE. We examined review articles and contacted investigators. We also checked registers of ongoing clinical trials, citation lists of included studies, key textbooks, grey literature, and previous systematic reviews for potentially relevant studies.

Selection Criteria: We sought randomised controlled trials (RCTs) that compared immediate postpartum versus delayed insertion of contraceptive implant for contraception.

Data Collection And Analysis: Two review authors (JS, YW) independently screened titles and abstracts of the search results, and assessed the full-text articles of potentially relevant studies for inclusion. They extracted data from the included studies, assessed risk of bias, compared results, and resolved disagreements by consulting a third review author (PL or SK). We contacted investigators for additional data, where possible. We computed the Mantel-Haenszel risk ratio (RR) with 95% confidence interval (CI) for binary outcomes and the mean difference (MD) with 95% CI for continuous variables.

Main Results: Three studies that included 410 participants met the inclusion criteria of the review. We did not identify any ongoing trials. Two included studies were at low risk of selection, attrition, and reporting biases, but were at high risk of performance and detection biases due to the inability to blind participants to the intervention. One included study was at high risk of attrition bias. The overall quality of the evidence for each comparison ranged from very low to moderate; the main limitations were risk of bias and imprecision.Initiation rate of contraceptive implants at the first postpartum check-up visit was significantly higher in the immediate insertion group than in the delayed insertion group (RR 1.41, 95% CI 1.28 to 1.55; three studies, 410 participants; moderate quality evidence).There appeared to be little or no difference between the groups in the continuation rate of contraceptive implant used at six months after insertion (RR 1.02, 95% CI 0.93 to 1.11; two studies, 125 participants; low quality evidence) or at 12 months after insertion (RR 1.04; 95% CI 0.81 to 1.34; one study, 64 participants;very low quality evidence)Women who received an immediate postpartum contraceptive implant insertion had a higher mean number of days of abnormal vaginal bleeding within six weeks postpartum (MD 5.80 days, 95% CI 3.79 to 7.81; one study, 215 participants; low quality evidence) and a higher rate of other side effects in the first six weeks after birth (RR 2.06, 95% CI 1.38 to 3.06; one study, 215 participants; low quality evidence) than those who received a delayed postpartum insertion. There appeared to be little or no difference between the groups in heavy, irregular vaginal bleeding or associated severe cramping within 12 months (RR 1.01, 95% CI 0.72 to 1.44, one study, 64 participants;very low quality evidence).It was unclear whether there was any difference between the groups in scores for participant satisfaction on a 0-10 scale (MD -0.40, 95% CI -1.26 to 0.46, low quality evidence), or in rates of unintended pregnancy (RR 1.82, 95% CI 0.38 to 8.71, 1 RCT, 64 women, very low quality evidence) at 12 months, or in rate of breastfeeding rate at six months (RR 2.01, 95% CI 0.72 ro 5.63, 1 RCT, 64 women, very low quality evidence) rate did not differ significantly between the groups.

Authors' Conclusions: Evidence from this review indicates that the rate of initiation of contraceptive implant at the first postpartum check-up visit was higher with immediate postpartum insertion than with delayed insertion. There appeared to be little or no difference between the groups in the continuation rate of contraceptive implant use at 6 months. It was unclear whether there was any difference between the groups in continuation of contraceptive use at 12 months or in the unintended pregnancy rate at 12 months.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6478153PMC
http://dx.doi.org/10.1002/14651858.CD011913.pub2DOI Listing

Publication Analysis

Top Keywords

low quality
32
contraceptive implant
28
quality evidence
28
difference groups
20
postpartum insertion
16
versus delayed
12
delayed postpartum
12
unintended pregnancy
12
included studies
12
delayed insertion
12

Similar Publications

Pancreatic ductal adenocarcinoma (PDAC) is projected to be the second leading cause of cancer-related death by 2030. Early identification is rare, with a 5-year overall survival (OS) of less than 10%. Advances in the understanding of PDAC tumor biology are needed to improve these outcomes.

View Article and Find Full Text PDF

Purpose: This report details the recommendations of a Nursing Best Practice Working Group, which aims to advance best practice in the use of 5-aminolevulinic acid (5-ALA) fluorescence-guided surgery (FGS) in patients with high-grade glioma (HGG).

Design: Quality Improvement Project.

Methods: These recommendations were gathered during a meeting of a Nursing Best Practice Working Group comprising expert nurses and practice administrators from five US centers of excellence in the management of HGG.

View Article and Find Full Text PDF

Photon-Counting CT Effects on Sensitivity for Liver Lesion Detection: A Reader Study Using Virtual Imaging.

Radiology

January 2025

From the Department of Radiology, Duke University Hospital, 2301 Erwin Rd, Box 3808, Durham, NC 27701 (B.W.T., K.R.K., B.C.A., S.P.T., D.E.K., B.H., M.R.B., D.M., E.S., E.A.); Department of Biostatistics and Bioinformatics (N.F., S.M., A.E.) and Department of Medical Physics (W.P.S., E.S., E.A.), Duke University, Durham, NC.

Background Detection of hepatic metastases at CT is a daily task in radiology departments that influences medical and surgical treatment strategies for oncology patients. Purpose To compare simulated photon-counting CT (PCCT) with energy-integrating detector (EID) CT for the detection of small liver lesions. Materials and Methods In this reader study (July to December 2023), a virtual imaging framework was used with 50 anthropomorphic phantoms and 183 generated liver lesions (one to six lesions per phantom, 0.

View Article and Find Full Text PDF

COVID-19 disease, triggered by SARS-CoV-2 virus infection, has led to more than 7.0 million deaths worldwide, with a significant fraction of recovered infected people reporting postviral symptoms. Smart surfaces functionalized with nanoparticles are a powerful tool to inactivate the virus and prevent the further spreading of the disease.

View Article and Find Full Text PDF

With the rapid decline in the levelized cost, offshore wind power offers a new option for the clean energy transition of the power sector in China's coastal areas. Here, we develop a power system capacity expansion and operation optimization model to simulate the penetration of offshore wind power in China and quantify the associated health effects. We find that offshore wind power has great potential in mitigating the negative impacts of existing coal-fired power emissions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!