Introduction: Inappropriate implantable cardioverter-defibrillator (ICD) shocks, commonly caused by atrial fibrillation (AF), are associated with an increased mortality. Because impaired left atrial (LA) function predicts development of AF, we hypothesized that impaired LA function predicts inappropriate shocks beyond a history of AF.
Methods And Results: We prospectively analyzed the association between LA function and incident inappropriate shocks in primary prevention ICD candidates. In the Prospective Observational Study of ICD (PROSE-ICD), we assessed LA function using tissue-tracking cardiac magnetic resonance (CMR) prior to ICD implantation. A total of 162 patients (113 males, age 56 ± 15 years) were included. During the mean follow-up of 4.0 ± 2.9 years, 26 patients (16%) experienced inappropriate shocks due to AF (n = 19; 73%), supraventricular tachycardia (n = 5; 19%), and abnormal sensing (n = 2; 8%). In univariable analyses, inappropriate shocks were associated with AF history prior to ICD implantation, age below 70 years, QRS duration less than 120 milliseconds, larger LA minimum volume, lower LA stroke volume, lower LA emptying fraction, impaired LA maximum and preatrial contraction strains (S and S ), and impaired LA strain rate during left ventricular systole and atrial contraction (SR and SR ). In multivariable analysis, impaired S (hazard ratio [HR]: 0.96, P = 0.044), S (HR: 0.94, P = 0.030), and SR (HR: 0.25, P < 0.001) were independently associated with inappropriate shocks. The receiver-operating characteristics curve showed that SR improved the predictive value beyond the patient demographics including AF history (P = 0.033).
Conclusion: Impaired LA function assessed by tissue-tracking CMR is an independent predictor of inappropriate shocks in primary prevention ICD candidates beyond AF history.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5528170 | PMC |
http://dx.doi.org/10.1111/jce.13234 | DOI Listing |
J Cardiovasc Dev Dis
December 2024
Cardiac Electrophysiology Division, Cardiology Center, Department of Internal Medicine, University of Szeged, 6725 Szeged, Hungary.
Background: An atrioventricular defibrillator system with a floating atrial dipole (VDD ICD) can provide atrial sensing by a single lead. Our aim was to compare the arrhythmia detection efficacy of VDD ICDs with conventional single- (VVI) and dual-chamber (DDD) defibrillators.
Methods: Data from consecutive patients undergoing ICD implantation were retrospectively analyzed.
BMJ Open
December 2024
Emergency Department, Lausanne University Hospital, Lausanne, Switzerland.
Objectives: To develop and validate a simplified Bleeding Audit Triage Trauma (sBATT) score for use by lay persons, or in areas and environments where physiological monitoring equipment may be unavailable or inappropriate.
Design: The sBATT was derived from the original BATT, which included prehospital systolic blood pressure (SBP), heart rate, respiratory rate, Glasgow Coma Scale (GCS), age and trauma mechanism. Variables suitable for lay interpretation without monitoring equipment were included (age, level of consciousness, absence of radial pulse, tachycardia and trapped status).
JACC Adv
January 2025
Division of Cardiology, Department of Medicine, Warren Alpert Medical School of Brown University, and Lifespan Cardiovascular Institute, Providence, Rhode Island, USA.
This state-of-the-art review describes the potential etiologies, pathophysiology, and management of mixed shock in the context of a proposed novel classification system. Cardiogenic-vasodilatory shock occurs when cardiogenic shock is complicated by inappropriate vasodilation, impairing compensatory mechanisms, and contributing to worsening shock. Vasodilatory-cardiogenic shock occurs when vasodilatory shock is complicated by myocardial dysfunction, resulting in low cardiac output.
View Article and Find Full Text PDFInt J Cardiol Congenit Heart Dis
March 2024
Sydney Medical School, The University of Sydney, Camperdown, Australia.
Background: Brady- and tachyarrhythmias commonly complicate adult congenital heart disease (ACHD). Permanent pacemakers (PPMs) or implantable cardioverter-defibrillators (ICDs) are often utilised to prevent morbidity or mortality related to arrhythmia, but can also be associated with significant morbidity themselves.
Methods: We analysed outcomes from patients in our comprehensive ACHD database who were seen at least twice since 2000 and once since 2018.
Int J Cardiol Congenit Heart Dis
March 2024
Department of Cardiovascular Diseases, Mayo Clinic, Jacksonville, FL, USA.
Aims: Patients with D-transposition of the great arteries (D-TGA) and atrial switch experience late morbidity and mortality related to atrial arrhythmias and systemic right ventricular (SRV) failure. We sought to analyze the influence of atrial arrhythmias on long-term outcomes in this group.
Methods: A retrospective review of all patients with D-TGA and atrial switch followed at a tertiary care center was performed.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!