DMSO Assisted Electrospray Ionization for the Detection of Small Peptide Hormones in Urine by Dilute-and-Shoot-Liquid-Chromatography-High Resolution Mass Spectrometry.

J Am Soc Mass Spectrom

Department of Clinical Chemistry, Microbiology and Immunology, Doping Control Laboratory, Ghent University, Technologiepark 30 B, B-9052, Zwijnaarde, Belgium.

Published: August 2017

The mobile phase additive (DMSO) has been described as a useful tool to enhance electrospray ionization (ESI) of peptides and proteins. So far, this technique has mainly been used in proteomic/peptide research, and its applicability in a routine clinical laboratory setting (i.e., doping control analysis) has not been described yet. This work provides a simple, easy to implement screening method for the detection of doping relevant small peptides (GHRPs, GnRHs, GHS, and vasopressin-analogues) with molecular weight less than 2 kDa applying DMSO in the mobile phase. The gain in sensitivity was sufficient to inject the urine samples after a 2-fold dilution step omitting a time consuming sample preparation. The employed analytical procedure was validated for the qualitative determination of 36 compounds, including 13 metabolites. The detection limits (LODs) ranged between 50 and 1000 pg/mL and were compliant with the 2 ng/mL minimum detection level required by the World Anti-Doping Agency (WADA) for all the target peptides. To demonstrate the feasibility of the work, urine samples obtained from patients who have been treated with desmopressin or leuprolide and urine samples that have been declared as adverse analytical findings were analyzed. Graphical Abstract ᅟ.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s13361-017-1670-7DOI Listing

Publication Analysis

Top Keywords

urine samples
12
electrospray ionization
8
mobile phase
8
dmso assisted
4
assisted electrospray
4
detection
4
ionization detection
4
detection small
4
small peptide
4
peptide hormones
4

Similar Publications

Two observational studies were conducted to support an initiative to qualify translational kidney safety biomarkers as clinical drug development tools that identify tubular injury prior to changes in estimated glomerular filtration rate (eGFR). Normal healthy volunteers provided three morning spot urine collections over 4 weeks. Patients undergoing surgical resection and intrathoracic cisplatin for malignant pleural mesothelioma provided urine samples pre- and postoperatively at 4, 8, and 12 hours and daily for 6 days.

View Article and Find Full Text PDF

LC-HRMS screening procedure for the detection of 11 different classes of prohibited substances in dried urine spots for doping control purposes.

Anal Bioanal Chem

January 2025

Doping Control Laboratory, Department of Diagnostic Sciences, Ghent University, Block B, Ottergemsesteenweg 460, BE-9000, Ghent, Belgium.

Dried urine spots have recently been proposed as an alternative matrix in the anti-doping field. Drying urine may open the opportunity to limit microbial and thermal degradation of the prohibited substances during transportation to the anti-doping laboratories without the need for refrigeration or freezing. In this study, a multi-targeted initial testing procedure was developed for the determination of 237 prohibited drugs/metabolites from 11 different classes in dried urine spots.

View Article and Find Full Text PDF

Flow prediction in sound-based uroflowmetry.

Sci Rep

January 2025

Department of Signal Theory and Communications, Universidad de Valladolid, 47002, Valladolid, Spain.

Sound-based uroflowmetry (SU) offers a non-invasive alternative to traditional uroflowmetry (UF) for evaluating lower urinary tract dysfunctions, enabling home-based testing and reducing the need for clinic visits. This study compares SU and UF in estimating urine flow rate and voided volume in 50 male volunteers (aged 18-60), with UF results from a Minze uroflowmeter as the reference standard. Audio signals recorded during voiding were segmented and machine learning algorithms (gradient boosting, random forest, and support vector machine) estimated flow parameters from three devices: Ultramic384k, Mi A1 smartphone, and Oppo smartwatch.

View Article and Find Full Text PDF

Evaluation of renal functional reserve with oral protein load or new ultrasound test.

J Nephrol

January 2025

Department of Medicine, Surgery and Neurosciences, Nephrology, Dialysis and Transplantation Unit, University Hospital of Siena, Siena, Italy.

Background: Renal functional reserve (RFR) measures the difference between the stimulated glomerular filtration rate (GFR) and the baseline GFR to detect early signs of renal functional decline. The protein load test (RFR-T) is the gold standard for RFR assessment but is a complicated procedure. Renal intraparenchymal resistance index (RRI) variation test (DRRI-T) is a non-invasive method to measure renal function reserve using ultrasound.

View Article and Find Full Text PDF

β-cyclodextrin polymers as a new sorbent for solid-phase extraction of xenobiotics in Urine.

J Hazard Mater

December 2024

School of Environmental Science and Engineering, Tianjin University, Tianjin 300072, China. Electronic address:

This study systematically assessed the performance of a newly developed solid-phase extraction (SPE) material, cellulose-supported aminated β-cyclodextrin polymer (amine-β-CDP@Cellulose), in determining 44 xenobiotics, encompassing endocrine-disrupting chemicals (EDCs), pharmaceuticals, and food additives in urine samples. The primary objective of the research was to synthesize a new sorbent, optimize the extraction protocol, and elucidate the underlying adsorption and desorption mechanisms. Following optimization, it was observed that amine-β-CDP@Cellulose achieved recoveries ranging from 80 % to 120 % for 28 of the 44 targeted xenobiotics, with only three compounds showing recoveries below 50 %.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!