A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Assessment of vascular response to BiOSS LIM C stents vs Orsiro stents in the porcine coronary artery model. | LitMetric

Aims: The optimal treatment strategy for coronary bifurcation lesions is still unknown. The aim of the study was to assess applicability of the new cobalt-chromium version of the sirolimus-eluting dedicated bifurcation BiOSS LIM C stent in comparison with regular sirolimus-eluting Orsiro  stent in a porcine coronary model.

Methods: A total of 13 BiOSS LIM C stents and 6 Orsiro stents were implanted in normal nonatherosclerotic porcine straight coronary arteries of six animals using 1.2:1.0 stent-to-artery ratio. Stent geometry and morphology were evaluated by Faxitron imaging. Vascular response was assessed by quantitative coronary angiography (QCA), optical coherence tomography (OCT), and histological analyses.

Results: OCT performed at 28 days confirmed that all stents were patent with no signs of thrombus. In morphometric analysis, no differences between groups regarding stent diameter (P=.141), neointima area (P=.247), % area stenosis (P=.293), or % diameter stenosis (P=.069) were observed. Also, no significant differences were noted between groups regarding their histopathology scores. The injury and inflammation scores were low (mean grade<1) in all groups.

Conclusions: The novel BiOSS LIM C stent demonstrates good short-term vascular effects in a porcine coronary bifurcation model which are comparable with Orsiro stents.

Download full-text PDF

Source
http://dx.doi.org/10.1111/1755-5922.12267DOI Listing

Publication Analysis

Top Keywords

bioss lim
12
vascular response
8
lim stents
8
stents orsiro
8
orsiro stents
8
porcine coronary
8
differences groups
8
stents
5
coronary
5
assessment vascular
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!