Herein, we present the design technique of a resonant rectifier for piezoelectric (PE) energy harvesting. We propose two diode equivalents to reduce the voltage drop in the rectifier operation, a minuscule-drop-diode equivalent (MDDE) and a low-drop-diode equivalent (LDDE). The diode equivalents are embedded in resonant rectifier integrated circuits (ICs), which use symmetric bias-flip to reduce the power used for charging and discharging the internal capacitance of a PE transducer. The self-startup function is supported by synchronously generating control pulses for the bias-flip from the PE transducer. Two resonant rectifier ICs, using both MDDE and LDDE, are fabricated in a 0.18 μm CMOS process and their performances are characterized under external and self-power conditions. Under the external-power condition, the rectifier using LDDE delivers an output power of 564 μW and a rectifier output voltage of 3.36 V with a power transfer efficiency of 68.1%. Under self-power conditions, the rectifier using MDDE delivers a of 288 μW and a of 2.4 V with a corresponding efficiency of 78.4%. Using the proposed bias-flip technique, the power extraction capability of the proposed rectifier is 5.9 and 3.0 times higher than that of a conventional full-bridge rectifier.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5426825 | PMC |
http://dx.doi.org/10.3390/s17040901 | DOI Listing |
BMC Med Educ
January 2025
Department of Radiology and Tianjin Key Lab of Functional Imaging and Tianjin Institute of Radiology and State Key Laboratory of Experimental Hematology, Tianjin Medical University General Hospital, Tianjin, 300052, China.
Background: National Medical Licensing Examination (NMLE) is the entrance exam for medical practice in China, and its general medical knowledge test (GMKT) evaluates abilities of medical students to comprehensively apply medical knowledge to clinical practice. This study aimed to identify nonacademic predictors of GMKT performance, which would benefit medical schools in designing appropriate strategies and techniques to facilitate the transition from medical students to qualified medical practitioners.
Methods: In 1202 medical students, we conducted the deletion-substitution-addition (DSA) and structural equation model (SEM) analyses to identify nonacademic predictors of GMKT performance from 98 candidate variables including early life events, physical conditions, psychological and personality assessments, cognitive abilities, and socioeconomic conditions.
Sci Rep
January 2025
Department of Electronics, Information and Communication Engineering, Kangwon National University, Samcheok, Republic of Korea.
Detecting brain tumours (BT) early improves treatment possibilities and increases patient survival rates. Magnetic resonance imaging (MRI) scanning offers more comprehensive information, such as better contrast and clarity, than any alternative scanning process. Manually separating BTs from several MRI images gathered in medical practice for cancer analysis is challenging and time-consuming.
View Article and Find Full Text PDFRev Sci Instrum
January 2025
State Key Laboratory of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi 710049, China.
In this paper, we present the development of a nanosecond pulse generator utilizing semiconductor opening switches (SOS), designed to deliver high voltage and operate at a high repetitive frequency. The pulse generator comprises three main components: a primary charging unit, a magnetic pulse compression unit, and an SOS magnification unit. To ensure stable operation of the high-power charging unit at high repetitive frequencies, a rectifying resonant charging and energy recovery circuit are implemented, providing a 1 kV charging voltage at a 3 kHz repetition rate.
View Article and Find Full Text PDFMethodsX
December 2024
Department of Radiology and Imaging Sciences, University of Utah, 729 Arapeen Drive, Salt Lake City, UT, 84109, USA.
This study introduces a comprehensive hardware-software framework designed to enhance the quality of block face image capture-an essential intermediary step for registering 2D histology images to ex vivo magnetic resonance (MR) images. A customized camera mounting and lighting system is employed to maintain consistent relative positioning and lighting conditions. Departing from traditional transparent paraffin, dyed paraffin is utilized to enhance contrast for subsequent automatic segmentation.
View Article and Find Full Text PDFNeurosci Bull
December 2024
State Key Laboratory of Pharmaceutical Biotechnology, National Resource Center for Mutant Mice, Department of Anesthesiology, Nanjing Drum Tower Hospital, and Department of Physiology, School of Life Sciences, Nanjing University, Nanjing, 210023, China.
The ventral anterior (VA) nucleus of the thalamus is a major target of the basal ganglia and is closely associated with the pathogenesis of Parkinson's disease (PD). Notably, the VA receives direct innervation from the hypothalamic histaminergic system. However, its role in PD remains unknown.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!