A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A New Dispersive Liquid-Liquid Microextraction Method for Preconcentration and Determination of Aluminum, Iron, Copper, and Lead in Real Water Samples by HPLC. | LitMetric

A New Dispersive Liquid-Liquid Microextraction Method for Preconcentration and Determination of Aluminum, Iron, Copper, and Lead in Real Water Samples by HPLC.

J AOAC Int

Yildiz Technical University, Faculty of Arts and Sciences, Department of Chemistry, Davutpasa Campus, 34220 Esenler, Istanbul, Turkey.

Published: September 2017

In this study, dispersive liquid-liquid microextraction coupled with HPLC with variable-wavelength detection was applied for the simultaneous determination of Al, Fe, Cu, and Pb in various water samples at trace levels. In the proposed method, all the system parameters in both the extraction and separation/determination steps, such as extraction and disperser solvent type and their volumes, complexing reagent concentration, salt addition, extraction and centrifugation times, and pH, were optimized to get not only high extraction efficiency but also lower LODs for the analytes. Hematoxylin was used as a complexing reagent, and carbon tetrachloride and methanol were chosen as the extraction and disperser solvents, respectively. Metal complexes were separated with a reversed-phase C18 column by isocratic elution, with methanol-tetrahydrofuran-water (20 + 12 + 68, v/v/v) as the mobile phase at a flow rate of 1.0 mL/min and detection at 575 nm. The accuracy of the method was checked by a Standard Reference Material of water (SRM 1643e), and the recovery values for the analytes were found in the range of 95.6-101.3%. Under the optimum conditions, the developed method was applied to tap water, bottled mineral water, lake water, and seawater for the accurate and sensitive determination of the analytes of interest.

Download full-text PDF

Source
http://dx.doi.org/10.5740/jaoacint.16-0376DOI Listing

Publication Analysis

Top Keywords

dispersive liquid-liquid
8
liquid-liquid microextraction
8
water samples
8
extraction disperser
8
complexing reagent
8
water
6
extraction
5
method
4
microextraction method
4
method preconcentration
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!