A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Weight-bearing recommendations after operative fracture treatment-fact or fiction? Gait results with and feasibility of a dynamic, continuous pedobarography insole. | LitMetric

Purpose: Rehabilitation after lower-extremity fractures is based on the physicians' recommendation for non-, partial-, or full weight-bearing. Clinical studies rely on this assumption, but continuous compliance or objective loading rates are unknown. The purpose of this study was to determine the compliance to weight-bearing recommendations by introducing a novel, pedobarography system continuously registering postoperative ground forces into ankle, tibial shaft and proximal femur fracture aftercare and test its feasibility for this purpose.

Methods: In this prospective, observational study, a continuously measuring pedobarography insole was placed in the patients shoe during the immediate post-operative aftercare after ankle, tibial shaft and intertrochanteric femur fractures. Weight-bearing was ordered as per the institutional standard and controlled by physical therapy. The insole was retrieved after a maximum of six weeks (28 days [range 5-42 days]). Non-compliance was defined as a failure to maintain, or reach the ordered weight-bearing within 30%.

Results: Overall 30 patients were included in the study. Fourteen (47%) of the patients were compliant to the weight-bearing recommendations. Within two weeks after surgery patients deviated from the recommendation by over 50%. Sex, age and weight did not influence the performance (p > 0.05). Ankle fracture patients (partial weight-bearing) showed a significantly increased deviation from the recommendation (p = 0.01).

Conclusions: Our study results show that, despite physical therapy training, weight-bearing compliance to recommended limits was low. Adherence to the partial weight-bearing task was further decreased over time. Uncontrolled weight-bearing recommendations should thus be viewed with caution and carefully considered as fiction. The presented insole is feasible to determine weight bearing continuously, could immediately help define real-time patient behaviour and establish realistic, individual weight-bearing recommendations.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00264-017-3481-7DOI Listing

Publication Analysis

Top Keywords

weight-bearing recommendations
20
weight-bearing
11
pedobarography insole
8
ankle tibial
8
tibial shaft
8
physical therapy
8
partial weight-bearing
8
patients
5
recommendations operative
4
operative fracture
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!