Objective: Comparison of the efficacy of Transitory Evoked Otoacoustic Emissions (TEOAEs) and Distortion Product Otoacoustic Emissions (DPOAEs) in a neonatal hearing screening protocol, based on a three-stage strategy.
Methods: In the first stage, a hearing screening using both evoked emissions was conducted in 3,480 neonates from March 2006 through January 2012. Both TEOAEs and DPOAEs were recorded. Neonates, who did not undergo the test before being discharged, were examined within 30 days at a scheduled appointment. Follow-up of the referred newborns (second-stage screening) was performed as an outpatient re-screening, within a month. The third-stage evaluation, i.e., the diagnostic testing, included a clinical otolaryngological examination, high-frequency tympanometry at 1,000 Hz and Auditory Brainstem Response (ABR) measurements.
Results: A total of 3,480 (97%) newborns (n =1,765 males) out of 3,595 infants were enrolled in the study. In the first-stage evaluation, 8.9 % of the infants were referred according to TEOAEs, while the percentage of the referred infants for DPΟΑΕs was 25.7 %. At this initial assessment stage, the specificity of TEOAES and DPOAEs were determined as 92% and 75%, while positive predictive values (PPV) were 3.8 % and 1.3 %, respectively. In the second stage of evaluation, the specificity of TEOAES and DPOAEs were 86 % and 76 %, while the PPV increased to 18 % and 15 %, respectively.
Conclusions: With a lower follow-up rate, TEOAEs testing was significantly easier to perform and more reliable compared to the DPOAEs test. Hippokratia 2016, 20(2): 104-109.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5388509 | PMC |
Ophthalmic Physiol Opt
January 2025
Vision and Hearing Sciences Research Centre, Anglia Ruskin University, Cambridge, UK.
Purpose: Wearable electronic low vision enhancement systems (wEVES) improve visual function but are not widely adopted by people with vision impairment. Here, qualitative research methods were used to investigate the usefulness of wEVES for people with age-related macular degeneration (AMD) after an extended home trial.
Methods: Following a 12-week non-masked randomised crossover trial, semi-structured interviews were completed with 34 participants with AMD, 64.
Sci Rep
January 2025
Imaging Department, Yantaishan Hospital, Yantai, China.
Noise-induced hearing loss (NIHL) is a common occupational condition. The aim of this study was to develop a classification model for NIHL on the basis of both functional magnetic resonance imaging (fMRI) and structural magnetic resonance imaging (sMRI) by applying machine learning methods. fMRI indices such as the amplitude of low-frequency fluctuation (ALFF), fractional amplitude of low-frequency fluctuation (fALFF), regional homogeneity (ReHo), degree of centrality (DC), and sMRI indices such as gray matter volume (GMV), white matter volume (WMV), and cortical thickness were extracted from each brain region.
View Article and Find Full Text PDFZhonghua Yi Xue Za Zhi
February 2025
Department of Neurology, Huashan Hospital, Fudan University, Shanghai 200040, China.
A total of 7 patients with type 1 infratentorial superficial siderosis(iSS-1)in Memory Clinic at Huashan Hospital, Fudan University from March 2019 to March 2023 were respectively collected to analyze the clinical characteristics and treatment, and followed up for 12 months. There were 7 patients, 2 males and 5 females, aged 56 (49-60) years. The 4 patients who underwent cognitive assessment had varying degree of cognitive impairment, with 2 patients exhibiting severe executive function impairment.
View Article and Find Full Text PDFSci Rep
January 2025
Mallinckrodt Institute of Radiology, Washington University School of Medicine, 4515 McKinley Ave., St. Louis, MO, 63110, USA.
Functional magnetic resonance imaging (fMRI) has dramatically advanced non-invasive human brain mapping and decoding. Functional near-infrared spectroscopy (fNIRS) and high-density diffuse optical tomography (HD-DOT) non-invasively measure blood oxygen fluctuations related to brain activity, like fMRI, at the brain surface, using more-lightweight equipment that circumvents ergonomic and logistical limitations of fMRI. HD-DOT grids have smaller inter-optode spacing (~ 13 mm) than sparse fNIRS (~ 30 mm) and therefore provide higher image quality, with spatial resolution ~ 1/2 that of fMRI, when using the several source-detector distances (13-40 mm) afforded by the HD-DOT grid.
View Article and Find Full Text PDFInt J Pediatr Otorhinolaryngol
January 2025
Northeast Ohio Medical University College of Medicine, 4209 St, OH-44, Rootstown, OH, 44272, USA; HEARS, LLC, 632 E. Market St, Ste B, Akron, OH, 44304, USA. Electronic address:
Objectives: Define the extent to which pathogenic GJB2 (gap junction beta-2) variants are responsible for non-syndromic hearing loss (NSHL) in the Asian population.
Methods: Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines were followed. CINAHL, Embase, and PubMed's MEDLINE were accessed from 1997 to 2023 using permutations of the MeSH terms: "Asian," ''Southeast Asian,'' "South Asian," "East Asian," "Southeastern Asian," and "GJB2.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!