Objective: The primary objective was to compare the frequency of first-attempt successful axillary vein cannulation by the Seldinger technique using out-of-plane ultrasound guidance versus in-plane imaging. Between the two ultrasound imaging planes, this study also compared the number of attempts that were necessary for the cannulation of the left axillary vein along with the number of needle redirections that had to be done for final cannulation of the vein. Incidence of complications and the number of times the procedure was abandoned also were compared between the two imaging planes.

Design: Prospective, randomized, interventional study.

Setting: Tertiary care cardiac center.

Participants: Cardiac surgical patients.

Interventions: Left axillary vein cannulation under ultrasound guidance by Seldinger technique.

Measurements And Main Results: The left axillary vein was accessed under ultrasound guidance in 86 consecutive adult cardiac surgical patients. They were randomized to out-of-plane (Group I, n = 43) and in-plane (Group II, n = 43) groups. In group I, the number of first-attempt cannulations was very high (p < 0.01). The number of attempts to access the vein was significantly lower in this group (p < 0.05). The duration for completion of the procedure was also less in group I with out-of-plane ultrasound guidance (p < 0.01). The number of needle redirections and the incidence of complications (arterial puncture, pneumothorax hematoma formation) were similar between the groups. There was no difference in the number of times the procedure was abandoned between the two groups. With an assumption that the first 10 patients in each group would suffice for overcoming the learning curve, the above aspects were analyzed further in each group. The first-attempt cannulation success continued to be significantly higher in the out-of-plane group.

Conclusions: Out-of-plane ultrasound imaging during axillary vein cannulation increased the chance of first-attempt successful cannulation. Axillary vein cannulation under out-of-plane ultrasound imaging also appeared to be quicker and was preferable in terms of the fewer number of attempts that were necessary for a successful vein cannulation.

Download full-text PDF

Source
http://dx.doi.org/10.1053/j.jvca.2017.02.011DOI Listing

Publication Analysis

Top Keywords

axillary vein
28
vein cannulation
24
left axillary
16
out-of-plane ultrasound
16
ultrasound guidance
16
ultrasound imaging
12
number attempts
12
vein
10
cannulation
10
ultrasound
8

Similar Publications

Introduction: Ultrasound (US)-guided axillary vein puncture is a safe and effective approach for cardiac implantable electronic device (CIED) implantation, and it is highly recommended by the current consensus document. However, only reports on small populations are available in the current literature regarding the comparison of this technique with other traditional approaches (subclavian vein blind puncture and cephalic vein surgical cutdown).

Purpose: We aimed to assess the effectiveness and safety of US- guided axillary vein puncture using a microintroducer kit for CIED implantation as compared to the aforementioned traditional approaches.

View Article and Find Full Text PDF

Hepatectomy with Hepatic Vein Resection and Reconstruction Under Total Vascular Exclusion and Venous Drainage via a Venovenous Bypass: An Additional Approach for Complex Hepatectomies.

Ann Surg Oncol

December 2024

Hepato-Pancreato-Biliary Surgery and Liver Transplantation, Pôle des Pathologies Hépatiques et Digestives, Hôpital de Hautepierre-Hôpitaux Universitaires de Strasbourg, Université de Strasbourg, Strasbourg, France.

Background: Total vascular exclusion (TVE) with liver hypothermic perfusion under venovenous bypass (VVB) is usually needed to perform hepatectomy with Inferior vena cava and hepatic veins resection-reconstruction. An alternative technique is represented by liver resection under intermittent pedicular clamping, IVC total clamping and VVB, without cold perfusion and liver outflow drainage through the VVB. PATIENTS AND METHODS: The patient is a 60-year-old woman with past medical history of right hepatectomy for leiomyosarcoma 14 years previously.

View Article and Find Full Text PDF

Background: Venous popliteal aneurysms are a rare but serious disease due to the risk of pulmonary embolism (PE). Aneurysms larger than 20 mm in diameter or with an embolic episode should be treated. The classic surgical technique is the tangential resection of the aneurysm with venorrhaphy, which may raise the risk of recurrence.

View Article and Find Full Text PDF

A 42-year-old female patient with a surgical history of iliac venous angioplasty with stenting developed dyspnea on exertion 9 months later. Chest computed tomography angiography revealed a fractured vascular stent in the right cardiac chamber. Doppler echocardiography confirmed that the stent was anchored by the tricuspid valve, causing mild obstruction of the right ventricular filling.

View Article and Find Full Text PDF

The selection of an appropriate implantable cardioverter-defibrillator (ICD) type and implantation strategy involves a myriad of considerations. While transvenous ICDs are standard, the rise of non-transvenous options like subcutaneous ICDs and extravascular ICDs is notable for their lower complication rates. Historical preferences for dual chamber ICDs have shifted to single-chamber ICDs.

View Article and Find Full Text PDF