Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
A simple low-cost method is proposed to fabricate a functionalized multi-wall carbon nanotube (MWCNT) with 1,1,3,3-tetramethyldisilazane (TMDS) molecule. The techniques of scanning electron microscope (SEM) with electron diffraction and energy dispersive X-ray (EDAX) analysis were applied to characterize the functionalized TMDS-MWCNT. The results showed that a MWCNT with high functionalization of TMDS can be obtained using this simple method. A new nanostructure sensor was constructed based on a glassy carbon electrode modified with TMDS-MWCNT (TMDS-MWCNT/GCE). It was found that the TMDS-MWCNT/GCE exhibits good catalytic activity toward oxidation of pramipexole (PPX) drug, leading to a concentration range of 0.8 to 600μM with a detection limit of 0.2μM at 3σ using the differential pulse voltammetry technique, a sensitivity of 0.084μAμM, and a correlation coefficient of 0.991. Furthermore, the TMDS-MWCNT/GCE was used for PPX detection in tablets and human blood serum samples. The method showed no interference from tablet excipients; hence, it can be useful and fit for the quantification of PPX in bulk and tablet dosage forms. The proposed method was validated successfully as applied to the quantification of the drug in tablet dosage forms. The accuracy of detection results using the proposed method was evaluated as excellent comparing with those obtained by the reference method.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.msec.2017.02.072 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!